ADJ Par Z Move [22/30] Led on tim
![ADJ Par Z Move [22/30] Led on tim](/views2/2013677/page22/bg16.png)
ADJ Products, LLC - www.adj.com - Par Z Move User Manual Page 21
Par Z Move Operating Instructions
Power On Time - With this function you are able to check the total power ON running
time of the unit. This time can NOT be reset.
NOTE: The displayed time represents the total power ON running time.
1. Access the main menu and press the UP or DOWN buttons so that “Information” is highlighted then
press ENTER.
2. Press the UP or DOWN buttons until “Fixture Life Time” is highlighted and press ENTER.
3. Press the UP or DOWN buttons until “Power On Time” is highlighted and press ENTER.
4. The total power ON running time of the xture will now be displayed. Press the MENU button to
exit.
P-On Time-R - With this function you are able to check current power ON running time
of the unit. This running time may not be the same as the total power ON running time displayed
under “POWER ON TIME”. This time CAN be reset.
NOTE: The displayed time represents the current power ON running time since the last reset.
1. Access the main menu and press the UP or DOWN buttons so that “Information” is highlighted then
press ENTER.
2. Press the UP or DOWN buttons until “Fixture Life Time” is highlighted and press ENTER.
3. Press the UP or DOWN buttons until “P-On Time-R” is highlighted and press ENTER.
4. The power ON running time of the xture will now be displayed. Press the MENU button to exit.
P-On Time Reset - With this function you can reset the current power ON running time
that is displayed under “P-ON TIME-R”.
1. Access the main menu and press the UP or DOWN buttons so that “Information” is highlighted then
press ENTER.
2. Press the UP or DOWN buttons until “Fixture Life Time” is highlighted and press ENTER.
3. Press the UP or DOWN buttons until “P-On Time Reset” is highlighted and press ENTER.
4. Use the UP or DOWN buttons to set the pass code to “50” and press ENTER. The P-ON TIME-R
will now be reset to “0”
LED On Time - With this function you are able to check the total LED ON time. This total
LED On time can NOT be reset.
NOTE: The displayed time represents the total LED ON time.
1. Access the main menu and press the UP or DOWN buttons so that “Information” is highlighted then
press ENTER.
2. Press the UP or DOWN buttons until “Fixture Life Time” is highlighted and press ENTER.
3. Press the UP or DOWN buttons until “LED On Time” is highlighted and press ENTER.
4. The total power ON running time of the xture will now be displayed. Press the MENU button to
exit.
Содержание
- Par z move 1
- Document version 2
- Due to additional product features and or enhancements an updated version of this document may be available online please check www adj com for the latest revision update of this manual before beginning installation and or programming 2
- Adj products llc www adj com par z move user manual page 3 4
- Par z move introduction 4
- Adj products llc www adj com par z move user manual page 4 5
- Par z move features 5
- Par z move warranty registration 5
- Adj products llc www adj com par z move user manual page 5 6
- Par z move safety precautions 6
- Adj products llc www adj com par z move user manual page 6 7
- Par z move safety precautions 7
- Adj products llc www adj com par z move user manual page 7 8
- Par z move installation 8
- Adj products llc www adj com par z move user manual page 8 9
- Par z move installation 9
- Adj products llc www adj com par z move user manual page 10 11
- Par z move dmx set up 11
- Adj products llc www adj com par z move user manual page 11 12
- Conductor 5 pin xlr male in 3 pin xlr female out 12
- Data compliment signal 12
- Data true signal 12
- Do not use 12
- Figure 3 12
- Ground shield 12
- Not used 12
- Par z move dmx set up 12
- Pin xlr dmx connectors some manufactures use 5 pin dmx 512 data cables for data transmission in place of 3 pin 5 pin dmx fixtures may be implemented in a 3 pin dmx line when inserting standard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores the chart below details a proper cable conversion 12
- Pin xlr to 5 pin xlr conversion 12
- Special note line termination when longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behavior a terminator is a 110 120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male xlr connector data and data this unit is inserted in the female xlr connector of the last unit in your daisy chain to terminate the line using a cable terminator adj part number z dmx t will decrease the possibilities of erratic behavior 12
- Adj products llc www adj com par z move user manual page 12 13
- Par z move dmx addressing 13
- Adj products llc www adj com par z move user manual page 13 14
- Par z move dmx modes values 14
- Adj products llc www adj com par z move user manual page 14 15
- Menu options description submenu 15
- Note shaded options represent the default settings 15
- Par z move system menu 15
- Adj products llc www adj com par z move user manual page 15 16
- Menu options description submenu 16
- Par z move system menu 16
- Adj products llc www adj com par z move user manual page 16 17
- Dmx addres 17
- Dmx ch mod 17
- No dmx statu 17
- Par z move operating instructions 17
- Adj products llc www adj com par z move user manual page 17 18
- P t feedbac 18
- P t spee 18
- Pan inver 18
- Par z move operating instructions 18
- Tilt inver 18
- Adj products llc www adj com par z move user manual page 18 19
- Dim mode 19
- Fan setting 19
- Hibernatio 19
- Led refresh rat 19
- Par z move operating instructions 19
- Adj products llc www adj com par z move user manual page 19 20
- Displa 20
- Par z move operating instructions 20
- Reset motor 20
- Adj products llc www adj com par z move user manual page 20 21
- Manual contro 21
- Par z move operating instructions 21
- Servic 21
- Adj products llc www adj com par z move user manual page 21 22
- Led on tim 22
- P on time 22
- P on time rese 22
- Par z move operating instructions 22
- Power on tim 22
- Adj products llc www adj com par z move user manual page 22 23
- Curren 23
- Led on time 23
- Led time rese 23
- Max resettabl 23
- Par z move operating instructions 23
- Adj products llc www adj com par z move user manual page 23 24
- Dmx value 24
- Fan info rpm 24
- Max not resettabl 24
- Par z move operating instructions 24
- Reset led temp 24
- Adj products llc www adj com par z move user manual page 24 25
- Error logs 25
- Max temp led o 25
- Max temp led of 25
- Par z move operating instructions 25
- Software versio 25
- Adj products llc www adj com par z move user manual page 25 26
- Dimmer 26
- Dimming curve ramp effect 26
- Par z move dimmer curve chart 26
- Adj products llc www adj com par z move user manual page 27 28
- Par z move cleaning 28
- Par z move multiple unit power linking 28
- Par z move trouble shooting 28
- Adj products llc www adj com par z move user manual page 28 29
- Par z move limited warranty 29
- Adj products llc www adj com par z move user manual page 29 30
- Model par z move 30
- Par z move specifications 30
Похожие устройства
- APart CM1008D Руководство по эксплуатации
- Rode SHURE BETA 87A Руководство по эксплуатации
- Tascam iM2W Руководство по эксплуатации
- JBL JRX112M Руководство по эксплуатации
- Volta WSE-3T Руководство по эксплуатации
- Behringer RV600 Руководство по эксплуатации
- Taurus BL-15 Руководство по эксплуатации
- Behringer TO800 Руководство по эксплуатации
- Zoom TAC-02 Руководство по эксплуатации
- ES-ACOUSTIC 153 AD Руководство по эксплуатации
- Yamaha YDP-142С Руководство по эксплуатации
- STAGG SLI KINGPAR22 Руководство по эксплуатации
- Yamaha YTS-82Z Руководство по эксплуатации
- Yamaha YTR-936S Руководство по эксплуатации
- Yamaha YSL-354SE Руководство по эксплуатации
- Yamaha YHR-567DS Руководство по эксплуатации
- Yamaha YSL-882O Xeno Руководство по эксплуатации
- Yamaha YSL-640 Руководство по эксплуатации
- Yamaha YFL-411II Руководство по эксплуатации
- Yamaha YCR-4330G Руководство по эксплуатации