Karcher HDS 801-4 E [16/260] Maintenance and care

Karcher HDS 801-4 E [16/260] Maintenance and care
16 English
Warning
Frost will destroy the not completely water
drained device.
Î Store in a frost free area.
If it is not possible to store frost free, shut
down device.
For longer work breaks or if a frost free stor-
age is not possible:
Î Drain water.
Î Flush device with anti-freeze agent.
Î Empty detergent tank.
Î Screw off water supply hose and high
pressure hose.
Î Unscrew closing stopper on the bottom
of the boiler and empty the boiler.
Î Operate device for max. 1 minute until
the pump and conduits are empty.
Danger
Risk of injury! Always disconnect the device
from the electrical power supply before per-
forming maintenance or repair work.
Warning
Only use original spare parts.
After each work, turn off device, refer to "Af-
ter each operation".
Î Set the appliance switch to "0".
Î Disconnect the main plug from the
socket.
Î Shut off water supply.
Î Activate hand spray gun until device is
pressure less.
Î Remove water connection.
Î Allow device to cool down.
Your Kärcher vender will inform you
about the performance of a periodic
safety inspection resp. signing of a
maintenance contract.
Î Check the power cord with mains plug
for damage before every use. If the
power cord is damaged, please arrange
immediately for the exchange by an au-
thorized customer service or a skilled
electrician.
Î Check the high pressure hose for dam-
ages (risk of bursting). Please arrange
for the immediate exchange of a dam-
aged high-pressure hose.
Î Check the pump for leaks. If the leak-
age is more than 3 drops per minute,
call Customer Service.
Î Clean the sieve in the water connection.
Î Clean filter at the detergent suck hose.
Î Check oil level.
In case of lacteous oil inform Kärcher
customer service immediately
Î Oil change.
Î Ready a catch bin for appr. 1 Liter oil.
Î loosen release screw.
Î Tighten release screw.
Î Fill oil slowly up to the MAX marking.
Note
Air pockets must be able to leak out.
For oil type refer to technical specifica-
tions.
Liquid softener tank is empty, due to
technical reasons a remainder stays in
the tank.
Î Refill.
Shutdown
Dump water
Maintenance and care
Maintenance intervals
Before each use
Weekly
After 500 operating hours, at least annu-
ally.
Oil change.
Dispose of old oil ecologically or turn in at
a gathering point.
Troubleshooting
Indicator lamp liquid softener glows

Содержание