Suzuki GSX-R600 (1996-2000) [275/429] Acaution

Содержание

7 9 ELECTRICAL SYSTEM GENERATOR COIL RESISTANCE INSPECTION Remove the frame cover and seats Refer to pages 6 3 and 4 Disconnect the generator couplers Using the multi circuit tester inspect the continuity between the three lead wires Also check that the stator core is insulated between the lead wire and the ground If there is no continuity replace the stator with a new one 09900 25008 Multi circuit tester set i Tester knob indication Resistance 0 Generator coil resistance Approx 0 3 fl Black Black oo fl Black Ground TACAUTION When using the multi circuit tester follow the instruc tion manual NOTE When making above test it is not necessary to remove the AC generator GENERATOR NO LOAD PERFORMANCE INSPECTION Remove the frame cover and seats Refer to pages 6 3 and 4 Disconnect the generator couplers Start the engine and keep it running at 5 000 r min Using the multi circuit tester measure the voltage between the three lead wires If the tester reads under the specified value replace the AC generator with a new one 09900 25008 Multi circuit tester set Tester knob indication Voltage Generator no load performance More than 55V AC at 5 000 r min When engine is cold NOTE Refer to page 3F 1 for generator replacing A CAUTION When using the multi circuit tester follow the instruc tion manual