Suunto D9 [56/122] Diving with the suunto d9
![Suunto D9 [56/122] Diving with the suunto d9](/views2/1013615/page56/bg38.png)
54
6. DIVING WITH THE SUUNTO D9
This section contains instructions on how to operate the dive
computer and interpret its displays. You will fi nd that this dive
computer is easy to use and read. Each display shows only
the data relevant to that specifi c diving situation.
6.1. DIVING IN AIR MODE [DIVEAIR]
The D9 has three diving modes: Air mode (DIVEair) for diving
with standard air only, Nitrox mode (DIVEean) for diving with
oxygen enriched mixtures and Gauge mode (DIVEgauge) for
use as bottomtimer and for freediving. The chosen dive mode
is displayed when the DIVE mode is accessed.
NOTE! The dive computer will remain in the Surface mode at
depths less than 1.2 m [4 feet]. At depths greater than 1.2 m
the instrument will go into the Diving mode (Fig. 6.1.).
6.1.1. BASIC DIVE DATA
All information on the display is labeled (Fig. 6.2.). During a
no-decompression stop dive, the following information will be
displayed:
- your present depth in meters [ft]
- the available no-decompression time in minutes as
NO DEC TIME
Fig. 6.1. Dive has just be-
gun and available no-de-
compression time is over
99min.
Fig. 6.2. Diving display.
Present depth is 19.8 m
[66 ft] and no-decompressi-
on stop time limit is 28 mi-
nutes. Maximum depth du-
ring this dive was 20.9 m
[70 ft], elapsed dive time is
15 minutes.
Содержание
- Quick reference guide 2
- Warning 6
- Warning 7
- Warning 8
- Warning 9
- Warning 10
- Table of contents 12
- Introduction 16
- Emergency ascents 18
- Safety precautions 18
- Dive computer limitations 19
- Nitrox 19
- Freediving 20
- Display and buttons 21
- Getting acquainted 21
- Water contacts 23
- Operating modes 24
- Wireless pressure transmission 25
- Pc interface 26
- Time display 26
- Time mode 26
- Stopwatch timer 27
- Daily alarm 28
- Time mode settings 28
- Dual time 29
- Backlight 30
- Accessing the compass 31
- Compass display 31
- Compass mode 31
- Calibrate 33
- Compass settings 33
- Declination 33
- If the calibration continues to fail contact an authorized suun to service center 35
- Activation and prechecks 36
- Before diving 36
- Dive mode activation 36
- Battery power indication 38
- Diving at altitude 39
- Personal adjustments 40
- Safety stops 43
- Deep stops 45
- Enabling the deep stops disables the recommended safety stops but mandatory safety stops due to e g continuous as cent rate violations are still prompted 45
- In this situation it is recommended to prolong your surface in terval time before your next dive 45
- The deep stop length can be set to 1 or 2 minutes 45
- The suunto d9 allows the user to choose a deep stop al gorithm instead of the traditional recommended safety stop deep stops are decompression stops that occur deeper than traditional stops with the purpose of minimizing microbubble formation and excitation 45
- The suunto rgbm model calculates deep stops iteratively placing the fi rst stop about halfway between the maximum depth and the ceiling depth after the fi rst deep stop is comp leted another deep stop will be prompted halfway to the cei ling and so on until the ceiling depth is reached 45
- Depth alarm 46
- Dive mode settings 46
- Dive time alarm 47
- Nitrox settings 47
- Personal altitude settings 48
- Sampling rate 48
- Rgbm settings 49
- Safety stops deepstops 49
- Tank pressure 49
- Hp code 50
- Installing the wireless transmitter 50
- Wireless transmission setup 50
- Pairing and code selection 51
- Transmission data 53
- If the dive is started without that the d9 and the transmitter have been properly paired the d9 will indicate that no cylinder data is available by displaying off fig 5 0e 54
- Table 5 pressure transmission related displays 54
- Basic dive data 56
- Diving in air mode diveair 56
- Diving with the suunto d9 56
- Bookmark 57
- Tank pressure data 58
- Ascent rate indicator 59
- Safety stops and deep stops 60
- Decompression dives 61
- Before diving in nitrox mode 67
- Diving in nitrox mode diveean 67
- Oxygen displays 69
- Oxygen limit fraction olf 69
- Gas change multiple breathing gas mixes 70
- Diving in gauge mode divegauge 71
- Using the compass in dive mode 72
- At the surface 73
- Surface interval 73
- Dive numbering 74
- Changed and the dive time will begin where it left off after 5 minutes on the surface subsequent dives are by defi nition repetitive the dive counter displayed in the plan ning mode will increment to the next higher number if another dive is made 75
- Repetitive dive planning 75
- Table 6 warning symbols 75
- The suunto d9 includes a dive planner that allows you to review the no decompressi on limits on a subsequent dive taking the residual nitrogen loading of previous dives in consideration the dive planning mode is explained in chapter 7 75
- Flying after diving 76
- Audible and visual alarms 77
- Error conditions 79
- Dive planning mode memplan 81
- Memory mode 81
- Dive logbook memlog 83
- Dive history memhis 85
- Additional features 86
- Suunto dive manager 87
- Suuntosports com 88
- Care and maintenance 92
- Care of your dive computer 92
- Important information 92
- Maintenance 94
- Water resistance inspection 94
- Battery replacement 95
- Computer battery replacement 95
- Wireless transmitter battery replacement 96
- Technical data 99
- Technical specification 99
- Suunto reduced gradient bubble model rgbm 104
- Table 10 no decompression time limits min for various depths m for the first dive of a series 106
- Table 10 no decompression time limits min for various depths ft for the first dive of a series 107
- Oxygen exposure 108
- Warranty 110
- Glossary 112
- Compass 119
- Compass light light compass light 119
- Modes and settings 119
- Settings 119
- Sub modes 119
- Duikcomputers 122
- M o s q u i t o 122
- Www suunto com 122
Похожие устройства
- Yamaha PSR-295 Инструкция по эксплуатации
- Stiga SILEX 50 R B 215010022/08 Инструкция по эксплуатации
- Moulinex ME 6061 Инструкция по эксплуатации
- D-Link DSL-500G Инструкция по эксплуатации
- Suunto D6i Инструкция по эксплуатации
- Yamaha PSR-3000 Инструкция по эксплуатации
- Viking HB 445 62410113900 Инструкция по эксплуатации
- Moulinex ME 4151 Инструкция по эксплуатации
- D-Link DSL-504T Инструкция по эксплуатации
- JVC TH-A75R Инструкция по эксплуатации
- JVC TH-A5R Инструкция по эксплуатации
- Suunto D6 Инструкция по эксплуатации
- Yamaha PSR-450 Инструкция по эксплуатации
- Dekok Uka-1320 Инструкция по эксплуатации
- Mega T 250 F BS 5,0 Инструкция по эксплуатации
- Samsung GT-B5512 Galaxy Y Pro Duos Инструкция по эксплуатации
- JVC TH-A55 Инструкция по эксплуатации
- Samsung GT-S6102 Galaxy Y Duos Инструкция по эксплуатации
- Suunto D4i Инструкция по эксплуатации
- Yamaha PSR-550 Инструкция по эксплуатации