Kramer Aspen RCP-1616 [39/52] Button lamp test
ASPEN 1616 AND 3232 RCP CONTROL PANELS
29
Lock
The LOCK button has 2 modes of operation. The mode can be set via the web pages.
1. Panel can be locked. The Lock button is enabled. It goes on/off when pressed.
The button will be RED when it is on. This is the default mode of operation.
2. Panel always locked, show status. The Lock button is disabled and is always
on. The button will be PURPLE.
In destination based mode, when the panel is locked (see above), the user can still
select any output button. The current input connected to this output will status by
illuminating the input button
While the panel is locked:
• The INPUT buttons will be disabled (nothing will happen when they are pressed):
• The following buttons will be off and disabled (nothing will happen when they are
pressed):
• FUNC button
• A button
• V button
• TAKE button
In source based mode, when the panel is locked (see above), the user can still select
any input button. The current outputs connected to this input will status by illuminating the
output buttons
While the panel is locked:
• The OUTPUT buttons will be disabled (nothing will happen when they are pressed):
• The following buttons will be off and disabled (nothing will happen when they are
pressed):
• FUNC button
• A button
• V button
• TAKE button
Button Lamp Test
1) On power up, press and hold input button 1 until all GREEN LEDs turn on
2) For input button 1, pressing the button will go through the following sequence
a. All BLUE LEDS on
b. All RED LEDS on
c. All LEDs off
d. Input button 1 GREEN LED on
e. Input button 1 BLUE LED on
f. Input button 1 RED LED on
g. Input button 1 off
h. All GREEN LEDs on
i. Go back to step a.
3) For all other buttons, each press of the button will cycle through each LED supported
by that button and off. If you continue to push the button, it will then repeat the
sequence. For example, if input button 2 is off, pressing it will go through the
following sequence.
a. GREEN
b. BLUE
c. RED
d. off
e. Go back to step a.
4) To exit test mode, remove and re-apply power to the unit.
Содержание
- Aspen rcp control panels models rcp 1616 and rcp 3232 1
- Sierra video 1
- User s manual 1
- User s manual 3
- Cautions 5
- Regulatory warnings safety information 5
- Warnings 5
- Cautions continued 6
- Fcc notice 6
- Warning 6
- Delivery damage inspection 7
- Emc regulatory notices 7
- International power supply cords 7
- North american power supply cords 7
- Power supply cords 7
- Table of contents 9
- Aspen rcp control panels 11
- Chapter 11
- Introduction 11
- Overview 11
- Model rcp 1616 12
- Model rcp 3232 12
- Chapter 13
- Dimensions 13
- Installation 13
- Introduction 13
- Rack mounting 13
- Ac power connections 14
- Connecting peripherals 14
- Button labelling 15
- Chapter 17
- Configuration 17
- Ethernet setup 17
- Changing password 18
- Hardware panel 20
- Overview 22
- Routing switcher 22
- Advanced 23
- System information 23
- Button brightness 24
- Button settings 25
- Input button mapping 28
- Output button mapping 28
- Output buttons 1 to 32 mapped to destination numbers 1 to 32 respectively salvo buttons 1 to 16 mapped to salvo numbers 1 to 16 respectively salvo buttons 17 to 32 mapped are all set to 0 29
- Salvo button mapping 29
- Salvo buttons 1 to 16 mapped to salvo numbers 1 to 16 respectively 29
- Layers 30
- Change password 31
- Communication setup 31
- If changes are made click on save if successful a reset needed reset now window will appear if not successful an error will be displayed 31
- Factory defaults 32
- Software updates 32
- Connection test 33
- Button colors 35
- Chapter 35
- Introduction 35
- Operation 35
- Rcp control panel operation 35
- Break away switching 36
- Destination based switching 36
- Switching the routing switcher 36
- V and a buttons 36
- Destination based status 37
- Source based status 38
- Source based switching 38
- Button lamp test 39
- Ip address 42
- Return to factory default 42
- Setup functions 42
- Button brightness 44
- Reset the ip address only to factory default 44
- Error indications 45
- Not connected to a routing switcher 45
- Power saving mode 45
- Rcp configuration fault 45
- Button lamp test 47
- Chapter 47
- Front panel error indications 47
- Introduction 47
- Rcp configuration fault 47
- Technical support 47
- Troubleshooting 47
- Chapter 49
- Specifications 49
- A general 51
- B limited warranty 51
- Chapter 51
- Warranty 51
- C cancellation 52
- D general 52
Похожие устройства
- Kramer Aspen RCP-3232 Руководства по эксплуатации
- Kramer Aspen RCP-7272 Руководства по эксплуатации
- Kramer Sierra Viper 6464CVR-64 Руководства по эксплуатации
- Kramer Sierra Ponderosa 6464HDR-64 Руководства по эксплуатации
- Kramer SierraView™ SVG Multi Viewer Руководства по эксплуатации
- Samsung Book Cover EF-BT550BSEGRU Инструкция по эксплуатации
- Samsung Level On Black (EO-PN900BBEGRU) Инструкция по эксплуатации
- Samsung S View Cover A5 Gold (EF-CA500BFEGRU) Инструкция по эксплуатации
- Samsung Level On Blue (EO-PN900BLEGRU) Инструкция по эксплуатации
- Samsung S Charger Pad EP-PG900I Black (EP-PG900IBRGRU) Инструкция по эксплуатации
- Samsung M-1814NR Инструкция по эксплуатации
- Samsung Flip Cover A3 White (EF-FA300BWEGRU) Инструкция по эксплуатации
- Samsung EP-PA510 White (EP-PA510BWRGRU) Инструкция по эксплуатации
- Samsung SP-54T6 HFR Инструкция по эксплуатации
- Samsung VC-8715 H Инструкция по эксплуатации
- Samsung VC-8716 VT Инструкция по эксплуатации
- Samsung VC-6025 V Инструкция по эксплуатации
- Samsung T100 S Инструкция по эксплуатации
- Samsung N620 S Инструкция по эксплуатации
- Samsung S821 GWL Инструкция по эксплуатации