Kramer Aspen RCP-1616 [45/52] Power saving mode
ASPEN 1616 AND 3232 RCP CONTROL PANELS
35
Power Saving Mode
Press and hold the FUNC until it turns BLUE.
Press and release the Salvo button while holding the FUNC button.
The LOCK button will indicate the power saving mode.
Blue if Enabled
Off if Disabled
Toggle the LOCK button to enable and disable.
Error Indications
Not Connected to a routing switcher
There are several reasons why the RCP cannot connect to the routing switcher. In any of
these situations the RCP will enter the “scrolling LED” state. The unit will turn on an LED
in each Input button one at a time then each Output button one at a time. Once it reaches
the last Output button, it will start again at the beginning. The RCP will use different
colors to indicate the different error situations.
Note that while in this state the user can press and hold the FUNC button to get to the
Setup functionality. When this happens, the “scrolling” will stop. When the user releases
the FUNC button, the “scrolling” will restart.
No network
If the RCP does not detect the network connection, the LEDs will cycle in RED.
No IP Address
If the RCP does not have a valid IP address, the LEDs will cycle in PURPLE. There are
two ways this can happen:
1. The panel is configured for DHCP and it has not received an IP address from the
DHCP server.
2. The user has put in a bad IP Address for this panel and/or this field has become
corrupt within the configuration.
Missing Routing Switcher
If the RCP detects all of the network settings are correct and it still cannot connect to the
routing switcher, the LEDs will cycle in GREEN.
RCP Configuration Fault
If there is a serious problem with the RCP where it cannot operate properly, the LOCK
and FUNC buttons will blink RED. All other buttons on the panel will be off.
Содержание
- Aspen rcp control panels models rcp 1616 and rcp 3232 1
- Sierra video 1
- User s manual 1
- User s manual 3
- Cautions 5
- Regulatory warnings safety information 5
- Warnings 5
- Cautions continued 6
- Fcc notice 6
- Warning 6
- Delivery damage inspection 7
- Emc regulatory notices 7
- International power supply cords 7
- North american power supply cords 7
- Power supply cords 7
- Table of contents 9
- Aspen rcp control panels 11
- Chapter 11
- Introduction 11
- Overview 11
- Model rcp 1616 12
- Model rcp 3232 12
- Chapter 13
- Dimensions 13
- Installation 13
- Introduction 13
- Rack mounting 13
- Ac power connections 14
- Connecting peripherals 14
- Button labelling 15
- Chapter 17
- Configuration 17
- Ethernet setup 17
- Changing password 18
- Hardware panel 20
- Overview 22
- Routing switcher 22
- Advanced 23
- System information 23
- Button brightness 24
- Button settings 25
- Input button mapping 28
- Output button mapping 28
- Output buttons 1 to 32 mapped to destination numbers 1 to 32 respectively salvo buttons 1 to 16 mapped to salvo numbers 1 to 16 respectively salvo buttons 17 to 32 mapped are all set to 0 29
- Salvo button mapping 29
- Salvo buttons 1 to 16 mapped to salvo numbers 1 to 16 respectively 29
- Layers 30
- Change password 31
- Communication setup 31
- If changes are made click on save if successful a reset needed reset now window will appear if not successful an error will be displayed 31
- Factory defaults 32
- Software updates 32
- Connection test 33
- Button colors 35
- Chapter 35
- Introduction 35
- Operation 35
- Rcp control panel operation 35
- Break away switching 36
- Destination based switching 36
- Switching the routing switcher 36
- V and a buttons 36
- Destination based status 37
- Source based status 38
- Source based switching 38
- Button lamp test 39
- Ip address 42
- Return to factory default 42
- Setup functions 42
- Button brightness 44
- Reset the ip address only to factory default 44
- Error indications 45
- Not connected to a routing switcher 45
- Power saving mode 45
- Rcp configuration fault 45
- Button lamp test 47
- Chapter 47
- Front panel error indications 47
- Introduction 47
- Rcp configuration fault 47
- Technical support 47
- Troubleshooting 47
- Chapter 49
- Specifications 49
- A general 51
- B limited warranty 51
- Chapter 51
- Warranty 51
- C cancellation 52
- D general 52
Похожие устройства
- Kramer Aspen RCP-3232 Руководства по эксплуатации
- Kramer Aspen RCP-7272 Руководства по эксплуатации
- Kramer Sierra Viper 6464CVR-64 Руководства по эксплуатации
- Kramer Sierra Ponderosa 6464HDR-64 Руководства по эксплуатации
- Kramer SierraView™ SVG Multi Viewer Руководства по эксплуатации
- Samsung Book Cover EF-BT550BSEGRU Инструкция по эксплуатации
- Samsung Level On Black (EO-PN900BBEGRU) Инструкция по эксплуатации
- Samsung S View Cover A5 Gold (EF-CA500BFEGRU) Инструкция по эксплуатации
- Samsung Level On Blue (EO-PN900BLEGRU) Инструкция по эксплуатации
- Samsung S Charger Pad EP-PG900I Black (EP-PG900IBRGRU) Инструкция по эксплуатации
- Samsung M-1814NR Инструкция по эксплуатации
- Samsung Flip Cover A3 White (EF-FA300BWEGRU) Инструкция по эксплуатации
- Samsung EP-PA510 White (EP-PA510BWRGRU) Инструкция по эксплуатации
- Samsung SP-54T6 HFR Инструкция по эксплуатации
- Samsung VC-8715 H Инструкция по эксплуатации
- Samsung VC-8716 VT Инструкция по эксплуатации
- Samsung VC-6025 V Инструкция по эксплуатации
- Samsung T100 S Инструкция по эксплуатации
- Samsung N620 S Инструкция по эксплуатации
- Samsung S821 GWL Инструкция по эксплуатации