Gigabyte GA-B75-D3V [40/88] 1st 2nd 3rd system fan speed control

Gigabyte GA-B75-D3V [40/88] 1st 2nd 3rd system fan speed control
BIOS Setup
- 40 -
& CPU Vcore/Dram Voltage/+3.3V/+12V
Displays the current system voltages.
& CPU/System Temperature
DisplayscurrentCPU/systemtemperature.
& CPU/System FAN Speed
DisplayscurrentCPU/systemfanspeeds.
& CPU Warning Temperature
Sets the warning threshold for CPU temperature. When CPU temperature exceeds the threshold, BIOS
will emit warning sound. Options are: Disabled (default), 60
o
C/140
o
F, 70
o
C/158
o
F, 80
o
C/176
o
F, 90
o
C/194
o
F.
& CPU/System Fan Fail Warning
Allows the system to emit warning sound if the CPU fan or system fans are not connected or fail. Check
the fan condition or fan connection when this occurs. (Default: Disabled)
& CPU Fan Speed Control
Allows you to determine whether to enable the CPU fan speed control function and adjust the fan speed.
Normal Allows the CPU fan to run at different speeds according to the CPU temperature. You can
adjust the fan speed with EasyTune based on your system requirements. (Default)
Silent Allows the CPU fan to run at slow speeds.
Manual Allows you to control the CPU fan speed under the Slope PWM item.
Disabled Allows the CPU fan to run at full speeds.
& Slope PWM
AllowsyoutocontroltheCPUfanspeed.ThisitemiscongurableonlywhenCPU Fan Speed Control is
set to Manual.Optionsare:0.75PWMvalue/
o
C~2.50PWMvalue/
o
C.
& 1st/2nd/3rd System Fan Speed Control
Allows you to determine whether to enable the system fan speed control function and adjust the fan speed.
Normal Allows the system fan to run at different speeds according to the system temperature. You
can adjust the fan speed with EasyTune based on your system requirements. (Default)
Silent Allows the system fans to run at slow speeds.
Manual Allows you to control the system fans speed under the Slope PWM item.
Disabled Allows the system fans to run at full speeds.
& Slope PWM
Allowsyoutocontrolthesystemfanspeed.Thisitemiscongurableonlywhen1st/2nd/3rd System Fan
Speed Control is set to Manual.Optionsare:0.75PWMvalue/
o
C~2.50PWMvalue/
o
C.