Zyxel IES4005 [136/236] Command description m p

Zyxel IES4005 [136/236] Command description m p
Chapter 16 Multicast
IES4005M User’s Guide
136
bandwidth <bandwidth>
Configures channel bandwidth for each group.
bandwidth: 0-100 in Mbps
C13
no igmp-mld group-privilege-
profile <profile-name> index
<index>
Removes an entry from the specified group privilege profile.
index: the entry index 1-16
C13
no igmp-mld group-privilege-
profile <profile-name>
Removes the specified group privilege profile. C 13
show igmp-mld group-privilege-
profile [<profile-name>]
Displays the contents of all privilege profiles or the specified
privilege profile.
E13
igmp-mld mvlan <mvid> [tr101-fw]
Enables the specified MVLAN. Without specifying tr101-fw, he IES
changes the MVLAN VID of IGMP/MLD reports to this VID if the
group address matches one of the group ranges configured in the
MVLAN mapping table.
mvid: 1 ~ 4093
tr101-fw: this optional configuration enables transparent
forwarding of IGMP/MLD messages on this VLAN. This is available
in TR-101 mode only.
C13
no igmp-mld mvlan <mvid>
Disables the specified MVLAN. C 13
show igmp-mld mvlan [<mvid>]
Displays the settings of all MVLAN or the specified MVLAN. E 13
igmp-mld mvlan-table <mvid> index
<index>
Configures an entry for the specified MVLAN mapping table for N:1
VLAN mapping (in TR-101 mode only). The MVLAN table is not
editable when tr101-fw is specified for the MVLAN.
mvid: 1 ~ 4093
index: the entry index 1 ~ 16
C13
group-range <start-ip> <end-ip>
Configures the group range, TR-101 mode only.
start-ip: 224.0.0.0 ~ 239.255.255.255
ff00:::: ~ ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff
end-ip: 224.0.0.0 ~ 239.255.255.255
ff00::~ ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff
C13
no igmp-mld mvlan-table <mvid>
index <index>
Removes an entry from the specified MVLAN mapping table, TR-
101 mode only.
mvid: 1 ~ 4093
index: the entry index 1 ~ 16
C13
no igmp-mld mvlan-table <mvid>
Removes the specified MVLAN mapping table, TR-101 mode only.
mvid: 1 ~ 4093
C13
interface dsl <slot/portlist>
Enters the sub-command mode for configuring the specified DSL
ports.
C13
igmp-mld mvlan <mvid> [uni-
vlan <uni-vid>]
Adds the specified DSL ports to an MVLAN. Specify uni-vlan to tag
the egress packets with the specified uni-vlan.
C13
igmp-mld mvlan <mvid> untag
Adds the specified DSL ports to an MVLAN and sends the egress
packets out untagged.
C13
no igmp-mld mvlan <mvid>
Removes the specified DSL port from an MVLAN. C 13
Table 91 IGMP/MLD Commands Summary (continued)
COMMAND DESCRIPTION M P

Содержание