Zyxel IES4005 [41/236] Specifications

Zyxel IES4005 [41/236] Specifications
Chapter 5 Power Supply Unit
IES4005M User’s Guide
41
5.2.3 Specifications
This table lists the specifications of the IES4005M-DC.
5.2.4 Procedure to Connect the DC Power
When installing the IES power wires on the IES4005M-DU, push the wires
firmly into the terminals as deep as possible and make sure that no
exposed (bare) wires can be seen or touched.
Use four wires to connect to each power module, two wires for the positive terminals and two wires
for the negative terminals.
1 Use a screwdriver to loosen the power module screws.
2 Slide the power module out partially to expose the power terminal screws.
3 Connect power wires to the negative power terminals on the front of the power module, and tighten
the terminal screw.
4 Connect the other ends of the power wires to the –48 V terminal on the power supply.
5 Connect power wires to the positive power terminals on the front of the IES power module, and
tighten the terminal screw.
6 Connect the other ends of the power wires to the ground terminal on the power supply.
7 Push the power module back in and tighten the screws.
8 Repeat the previous steps for the second power supply module.
Table 29 IES4005M-DC Specifications
ITEM VALUE
Dimensions (W x D x H) 130 mm x 252 mm x 41.2 mm
Maximum Power Consumption 38 W at the system’s maximum power consumption. The
lower the system’s overall power consumption, the lower
the IES4005M-DC’s power consumption.