CONEL CGU 04i [12/56] Cgu 04i description

Превью страниц Страница 12 / 56
CONEL CGU 04i [12/56] Cgu 04i description
CGU 04i DESCRIPTION
12
2.7.1 PORT1 (PORT2) connector - RS232
Panel socket RJ45 (RS232 – DCE - Data Communication Equipment).
Pin
number
Signal
mark
Description
Data flow
direction
1 RTS Request To Send Input
2 CTS Clear To Send Output
3 DTR Data Terminal Ready Input
4 DSR Data Set Ready – connected to +4 V through 330 Ohm Output
5 GND GROUND – signal ground
6 RXD Receive Data Output
7 CD Carrier Detect Output
8 TXD Transmit Data Input
Example of the meter connection to the CGU 04i:
Meter
Pin 1
RTS
Pin 2 – CTS
Pin 3 – DTR
Pin 4 – DSR
Pin 5 – GND
Pin 6 – RXD
Pin 7 – CD
Pin 8 – TXD
Modem CGU 04i
GND
RXD
TXD