CONEL CGU 04i — подключение питания для модемов: руководство по разъемам [23/56]

Превью страниц Страница 23 / 56
CONEL CGU 04i [23/56] Cgu 04i description
CGU 04i DESCRIPTION
23
2.7.6 PWR supply connector
Panel socket RJ12
Pin
number
Signal
mark
Description Direction
1 +UN Positive pole of DC supply voltage (10 to 30 V)
2 PWRSV Output open collector (Power Save) See CIO
description
Output
3 INAC Network supply presence check. Range 0 – 16 V Input
4 +UN Positive pole of DC supply voltage (10 to 30 V)
5 GND Negative pole of DC supply voltage
6 GND Negative pole of DC supply voltage
Note: Clamps 1-4 (+UN) and 5-6 (GND) are in the modem connect for bigger current overload.
On the power supply connector it is possible to use the signal INAC (NAP230) for
present AC voltage monitoring for power supply (it can be functional only in case of supply
accumulator backup).
Beware, on INAC (NAP230) input it isn't possible direct connect link voltage 230 V!
Circuit example:
DC supply
+
DC
Pin 1
+UN
Pin 2 – NC
Pin 3 – INAC
Pin 4 – +UN
Pin 5 – GND
Pin 6 – GND
Modem CGU 04i