CONEL CGU 04i — essential Safety Instructions for Communication Module Usage [4/56]
Превью страниц
Страница 4 /
56
![CONEL CGU 04i [4/56] Safety instructions](/views2/1190534/page4/bg4.png)
SAFETY INSTRUCTIONS
4
1. Safety instructions
Please observe the following safety instructions:
• The communication module must be used in compliance with all applicable international
and national laws and in compliance with any special restrictions regulating the utilization
of the communication module in prescribed applications and environments.
• Use only the original Conel company accessories. Thus you will prevent possible health
risks and damage to the devices and ensure compliance with all relevant provisions.
Unauthorised adjustments or use of unapproved accessories may result in damage to
the module and breach of applicable laws. Use of unapproved adjustments or accessories
may lead to cancellation of guarantee, which has no effects on your legal rights.
• The communication module CGU 04i must not be opened. Only the replacement of the
SIM card and expansion port is permitted.
•
Caution! The SIM card could be swallowed by small children.
• Voltage at the feed connector of the communication module must not be exceeded.
• Do not expose the communication module to extreme conditions. Protect it from dust,
moisture and heat.
• It is recommended not to use the communication module at petrol stations. We remind
users to observe the limitations of radio devices use at pump stations, chemical plants or
where explosives are being used.
• Switch the communication module off in a plane. Use of the communication module may
endanger plane’s functions, interfere with mobile network and be illegal. By not following
these instructions the customer risks cancellation or termination of telephone services,
prosecution or both.
• You have to be extremely careful when using the communication module in proximity to
medical devices, such as pacemakers or hearing aids.
• Close to TV sets, radios and PCs the module may cause interference.
• It is recommended to create proper copy or backup of all the important settings saved in
the device’s memory, to database by help program Radwin, reference [3].
Содержание
127- User s guide
- Gprs modem
- Declared system iso 9001 2009
- Cgu 04i
- Contents
- Symbols used
- Contents
- Safety instructions
- Caution the sim card could be swallowed by small childre
- General
- Examples of possible applications
- Description of the communication module cgu 04i
- Compatibility with other conel company modems
- Cgu 04i description
- Description of cgu 04i components
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Technical parameters
- Cgu 04i description
- Cgu 04i description
- Module status indication
- User interfaces connectors
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Modem cgu 04i
- Meter meter
- Circuit example of the equipment with a modem with data length more than 10 m
- Cgu 04i description
- At rs422 data cable more than 10m it is need to use overvoltage protection on the modem side
- Cgu 04i description
- Circuit example of the equipment with a modem with data length more than 10 m
- Cgu 04i description
- Modem cgu 04i
- If an m bus data cable more than 10m it is need to use overvoltage protection on the if an m bus data cable more than 10m it is need to use overvoltage protection on the router side
- Cgu 04i description
- Cgu 04i description
- The cio 2 modules are connected by the help of kd 51 cable cable 1 1 the cio 2 modules are connected by the help of kd 51 cable cable 1 1 the connector k1 is input k2 output to other cio 2 module by serial modems connection the addresses are automatically assigned in the direction from modem the addresses raises uplink 1 2 3 4 and 5 maximal module number in series is five see reference 4
- Circuit example
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Technical specifications of port 2
- Cgu 04i description
- Antenna connection
- Cgu 04i description
- Cgu 04i description
- Cgu 04i settings
- Cgu 04i description
- Service cable
- Standard accessories
- Cgu 04i description
- Additional accessories
- Cgu 04i description
- Assembly procedure
- Cgu 04i description
- Mechanical external dimensions and mounting recommendations
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Product marking
- Port2 marking
- Cgu 04i production label
- Cgu 04i description
- Cgu 04i description
- Expansion ports labels
- Cgu 04i description
- Basic parameters description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Module received cell 6e91 on channel 107 with level 77db
- If many cell with close signal levels 3 db be in danger of reselection switching between cells that caused bad time response or communication interruption in this case is needed to extend difference between signals
- Good quality gprs requirements
- Good placement of antenna is required for good function important factors are gsm cell signal strength and signal quality signal strength could me measured by function gprs receive signal strength measuring in program radwin second part is quality of signal there is no exact measurement good point of view is from data transfer statistic if number of lost packet is low signal quality is good
- Example station received these signals
- Change type from unidirectional to directional e g yagi direction or place of antenna after changing you must do measurements again
- Cgu 04i description
- Antenna installation for modems
- Adjacent cell signal below 12db to serving cell otherwise risk of interference
- What does it means
- Way to fix
- There is possible to reselection between channels 76 106 107 and 33 its level is so close
- There is possible to interference from channel 106 with level 79dbm
- The agnes system works with the aid of the gsm network the agnes stations contain gsm gprs modules which are on the radio channel connected to a certain gsm cell its signal can be evaluated with the aid of this function the function is used first of all when installing the station and checking its function from the obtained information the following can be read on which channel the station operates what is its signal strength what neighbour channels are available and what their signal is strength these data are often indispensable for the correct installation of the antenna
- Serving cell signal better than 90dbm
- Quality of the gprs signal
- Serving cell
- Run radwin function gprs receive signal strength measuring answer is information about serving and remaining cells output is from at commands at moni and at monp from gprs module
- Method of signal measurements
- Dedicated channel
- Cgu 04i description
- At moni command meaning
- Cgu 04i description
- At monp command meaning
- Expansion port mounting
- Expansion ports mounting
- Parts list and description
- Expansion ports mounting
- Description of i o signal evaluation and reception
- Cio description
- Cio analogue inputs and binary outputs
- Measuring other cgu 04i signals
- Cio description
- Technical parameters
- Output signal for disconnection of supply voltage
- Connecting cio signals to user device
- Cio description
- Cio description
- Protocols
- Products
- Links to related products of the manufacturer
- Systems
- Software
- References and links
- References
- Product disposal information
- Product disposal
- Complaints procedure
- Complaints procedure
- Warranty
- Warranty
Похожие устройства
-
CONEL CDX 800Инструкция по эксплуатации -
CONEL CDA 70Технические характеристики -
CONEL CDA 70Инструкция по эксплуатации -
CONEL XR5i v2EРуководство по конфигурации -
CONEL XR5i v2EТехнические характеристики -
CONEL XR5i v2EРуководство по подключению -
CONEL XR5i v2EИнструкция по эксплуатации -
CONEL XR5i v2FТехнические характеристики -
CONEL XR5i v2FРуководство по конфигурации -
CONEL XR5i v2FИнструкция по эксплуатации -
CONEL CR10 v2Руководство по подключению -
CONEL CR10 v2Технические характеристики
Follow these crucial safety instructions to ensure proper use of the communication module. Protect your device and health by adhering to guidelines and avoiding unauthorized modifications.