CGU 04i DESCRIPTION
5
2. Description of the communication module CGU 04i
2.1. General
GSM/GPRS communication module CGU 04i is a wireless data transmission device.
The communication module is one of the basic elements of AGNES GPRS system.
The system AGNES characteristics are described in reference [1]. GSM-GPRS infrastructure
is used for the wireless communication as a line layer. ARNEP protocol is implemented above
the line layer. The protocol ARNEP is described in reference [2]. On its basis the modules
create virtual private data network where data can be transferred between user devices via
any protocols.
One may simply imagine the CGU 04i module as a protocol converter between
the user device (PLC automatic, PC, data terminal, etc.) and GSM-GPRS infrastructure
of a mobile network operator, it provides the user with possibility to communicate simply
between all the systems. Apart from data transfers via GPRS the CGU 04i module enables
SMS.
The radio component GSM-GPRS is built in the CGU 04i module, consisting module
Cinterion.
GSM-GPRS module CGU 04i is controlled by communication 32-bit microprocessor.
It ensures GSM-GPRS communication, data transfer on serial user interfaces and a number
of diagnostic and service features. CGU 04i module in the basic version has one serial user
interface (communication port) RS232, one interface for direct connection of inputs
and outputs (CIO) for data collection and technological process management and one optional
user interface (RS232, RS422, RS485, M-BUSD, CNT). It is possible to set transfer
parameters and communication protocol for each user interface separately. As a result you
may communicate with various user interfaces using different communication protocols on
serial interface.
2.2. Examples of possible applications
• Security systems
• Telematics
• Telemetry
• Vending and dispenser machines
2.3. Compatibility with other Conel company modems
Regarding the communication and data transfers the CGU 04i module is compatible
with the older CGU 04 type (or CGU 02). This means it is possible to combine both types
in one network and simply extend an existing network of CGU 04 (CGU 02) modules
with new communication points using CGU 04i modules. CGU 04i provides some features not
included in the older CGU 04 type.
User and industrial communication protocol implemented on serial interfaces are
compatible with the protocols used for Conel radio modems (e.g. CDA 70). Thus you may
establish complex combined data networks consisting of both radio and GPRS modems.
Содержание
127- User s guide
- Gprs modem
- Declared system iso 9001 2009
- Cgu 04i
- Contents
- Symbols used
- Contents
- Safety instructions
- Caution the sim card could be swallowed by small childre
- General
- Examples of possible applications
- Description of the communication module cgu 04i
- Compatibility with other conel company modems
- Cgu 04i description
- Description of cgu 04i components
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Technical parameters
- Cgu 04i description
- Cgu 04i description
- Module status indication
- User interfaces connectors
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Modem cgu 04i
- Meter meter
- Circuit example of the equipment with a modem with data length more than 10 m
- Cgu 04i description
- At rs422 data cable more than 10m it is need to use overvoltage protection on the modem side
- Cgu 04i description
- Circuit example of the equipment with a modem with data length more than 10 m
- Cgu 04i description
- Modem cgu 04i
- If an m bus data cable more than 10m it is need to use overvoltage protection on the if an m bus data cable more than 10m it is need to use overvoltage protection on the router side
- Cgu 04i description
- Cgu 04i description
- The cio 2 modules are connected by the help of kd 51 cable cable 1 1 the cio 2 modules are connected by the help of kd 51 cable cable 1 1 the connector k1 is input k2 output to other cio 2 module by serial modems connection the addresses are automatically assigned in the direction from modem the addresses raises uplink 1 2 3 4 and 5 maximal module number in series is five see reference 4
- Circuit example
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Technical specifications of port 2
- Cgu 04i description
- Antenna connection
- Cgu 04i description
- Cgu 04i description
- Cgu 04i settings
- Cgu 04i description
- Service cable
- Standard accessories
- Cgu 04i description
- Additional accessories
- Cgu 04i description
- Assembly procedure
- Cgu 04i description
- Mechanical external dimensions and mounting recommendations
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Product marking
- Port2 marking
- Cgu 04i production label
- Cgu 04i description
- Cgu 04i description
- Expansion ports labels
- Cgu 04i description
- Basic parameters description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Cgu 04i description
- Module received cell 6e91 on channel 107 with level 77db
- If many cell with close signal levels 3 db be in danger of reselection switching between cells that caused bad time response or communication interruption in this case is needed to extend difference between signals
- Good quality gprs requirements
- Good placement of antenna is required for good function important factors are gsm cell signal strength and signal quality signal strength could me measured by function gprs receive signal strength measuring in program radwin second part is quality of signal there is no exact measurement good point of view is from data transfer statistic if number of lost packet is low signal quality is good
- Example station received these signals
- Change type from unidirectional to directional e g yagi direction or place of antenna after changing you must do measurements again
- Cgu 04i description
- Antenna installation for modems
- Adjacent cell signal below 12db to serving cell otherwise risk of interference
- What does it means
- Way to fix
- There is possible to reselection between channels 76 106 107 and 33 its level is so close
- There is possible to interference from channel 106 with level 79dbm
- The agnes system works with the aid of the gsm network the agnes stations contain gsm gprs modules which are on the radio channel connected to a certain gsm cell its signal can be evaluated with the aid of this function the function is used first of all when installing the station and checking its function from the obtained information the following can be read on which channel the station operates what is its signal strength what neighbour channels are available and what their signal is strength these data are often indispensable for the correct installation of the antenna
- Serving cell signal better than 90dbm
- Quality of the gprs signal
- Serving cell
- Run radwin function gprs receive signal strength measuring answer is information about serving and remaining cells output is from at commands at moni and at monp from gprs module
- Method of signal measurements
- Dedicated channel
- Cgu 04i description
- At moni command meaning
- Cgu 04i description
- At monp command meaning
- Expansion port mounting
- Expansion ports mounting
- Parts list and description
- Expansion ports mounting
- Description of i o signal evaluation and reception
- Cio description
- Cio analogue inputs and binary outputs
- Measuring other cgu 04i signals
- Cio description
- Technical parameters
- Output signal for disconnection of supply voltage
- Connecting cio signals to user device
- Cio description
- Cio description
- Protocols
- Products
- Links to related products of the manufacturer
- Systems
- Software
- References and links
- References
- Product disposal information
- Product disposal
- Complaints procedure
- Complaints procedure
- Warranty
- Warranty
Похожие устройства
-
CONEL CDX 800Инструкция по эксплуатации -
CONEL CDA 70Технические характеристики -
CONEL CDA 70Инструкция по эксплуатации -
CONEL XR5i v2EРуководство по конфигурации -
CONEL XR5i v2EТехнические характеристики -
CONEL XR5i v2EРуководство по подключению -
CONEL XR5i v2EИнструкция по эксплуатации -
CONEL XR5i v2FТехнические характеристики -
CONEL XR5i v2FРуководство по конфигурации -
CONEL XR5i v2FИнструкция по эксплуатации -
CONEL CR10 v2Руководство по подключению -
CONEL CR10 v2Технические характеристики
Изучите возможности беспроводного модуля связи для передачи данных через GSM/GPRS. Узнайте о его применении в системах безопасности, телематики и многом другом.