Moxa IKS-6728A-4GTXSFP-24-24-T [87/173] Relay warning event system

Moxa IKS-6728A-4GTXSFP-24-24-T [87/173] Relay warning event system
Moxa Command Line Interface (FW_5.x) Commands
2-77
turbo-chain Turbo chain
Defaults The default redundancy protocol mode is RSTP.
Command
Modes
Global configuration
Usage
Guidelines
N/A
Examples
MOXA(config)# redundancy mode rstp
MOXA(config)# redundancy mode turbo-ring-v1
MOXA(config)# redundancy mode turbo-ring-v2
MOXA(config)# redundancy mode turbo-chain
MOXA(config)# redundancy mode mst
Error
messages
N/A
Related
commands
show redundancy mode
relay-warning event (System)
Use relay-warning event global configuration commands to enable the warning events trigger to the relay.
Use the no form of this command to disable it.
Commands
relay-warning event { power-input1-fail | power-input2-fail | turbo-ring-break }
no relay-warning event { power-input1-fail | power-intput2-fail | turbo-ring-break }
Syntax
Description
relay-warning Configure relay warning
event System events
power-input1-fail Power input 1 failure (On->Off)
power-input2-fail
Power input 2 failure (On->Off)
turbo-ring-break Turbo Ring break
Defaults All system events are disabled by default.
Command
Modes
Global configuration
Usage
Guidelines
N/A
Examples
MOXA# configure terminal
MOXA(config)# relay-warning
MOXA(config)# relay-warning event power-input1-fail
MOXA(config)# relay-warning event power-input2-fail
MOXA(config)# relay-warning event turbo-ring-break
MOXA(config)# no relay-warning event power-input1-fail
MOXA(config)# no relay-warning event power-input2-fail
MOXA(config)# no relay-warning event turbo-ring-break
Error
messages
N/A
Related
commands
show relay-warning
relay-warning event (Port)
Use relay-warning event interface configuration commands to enable the warning events trigger to the relay.