Moxa IMC-21-S-SC [11/11] Federal communications commission statement

Moxa IMC-21-S-SC [11/11] Federal communications commission statement
- 11 -
Power
Input Voltage
12 to 48 VDC
Power Consumption
M-SC/ST:
271 mA @ 12 V
137 mA @ 24 V
77 mA @ 48 V
S-SC:
258 mA @ 12 V
129 mA @ 24 V
71 mA @ 48 V
Connection
Removable 3-contact Terminal Block
Overload Current
Protection
1.1 A
Reverse Polarity
Protection
Present
Mechanical
Casing
IP30 protection, plastic case
Dimensions
25 × 109 × 97 mm (W × H × D)
Weight
125 g
Installation
DIN-Rail mounting
Environmental
Operating Temperature
-10 to 60°C (14 to 140°F)
Storage Temperature
-40 to 70°C (-40 to 158°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety
UL 60950-1
EMI
FCC Part 15, CISPR (EN55022) class A
EMS EN61000-4-2 (ESD) Level 3
EN61000-4-3 (RS) Level 2
EN61000-4-4 (EFT) Level 2
EN61000-4-5 (Surge) Level 2
EN61000-4-6 (CS) Level 2
Shock
IEC 60068-2-27
Free Fall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Warranty
5 years
Federal Communications Commission Statement
FCC - This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC WARNING
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in
a
commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this
equipment
in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.