C320Turbo/PCIEL Connection Option and Cable Wiring
5-9
Pin No. Signal Pin No. Signal
1 GND 14 CLK-
2 DX+ 15 FSX+
3 DR+ 16 FSR+
4 GND 17 GND
5 GND 18 GND
6 GND 19 GND
7 -12V 20 +12V
8 +5V 21 +5V
9 +5V 22 +5V
10 +5V 23 +5V
11 CLK+ 24 FSX-
12 FSR- 25 DR-
13 DX-
10-signal-pin Link Cable (for long range extension only)
If the external power adapter is applied to the CPU/Basic Module, you will need to use the 10-pin cable
accompanying with the Long Range Extension Kit. The Control Board to CPU/Basic Module should have only 10
signal pins with the following pinouts.
WARNING
Make the link cable precisely according to the following pinout, otherwise you will risk damaging
the Control
Board and CPU/Basic Module.
Pin No. Signal Pin No. Signal
2 DX+ 14 CLK-
3 DR+ 15 FSX+
11 CLK+ 16 FSR+
12 FSR- 24 FSX-
13 DX- 25 DR-
You can connect the existing 10
-signal-pin cable to a 25-signal-pin cable to form a longer 2-segment
cable to extend the connection distance up to
100 meters (328 ft).