Moxa DA-UPCI-DK [32/45] Selecting a time input source

Moxa DA-SW08-RJ [32/45] Selecting a time input source
DA-IRIGB-4DIO-PCI104-EMC4 Module Driver and Utility Installation
3-18
Selecting a Time Input Source
From the Sync. to internal RTC Source drop-down list, select a time input source that you want to use.
Synchronizing with System Time
You can synchronize the RTC time with the system time. In the IRIG-B utility, select the Sync. internal RTC
to system time check box and enter the number of seconds to synchronize the time (the default is 10
seconds).
Configuring Digital Output and Input Status
The DA-IRIGB-4DIO-PCI104-EMC4 module features four digital outputs and three digital inputs. You can use
IRIG-B utility configure the digital output and digital input status.
To control a digital output, select or clear the associated check box. The following table shows the signal and
logic state for the check box.
Check box Signal Logic
Selected High 1
Not selected Low 0
To read status from a digital input, select or clear the associated check box. The following table shows the
signal and logic state.
Check box Signal Logic
Selected High 1
Not selected Low 0