DA-IRIGB-4DIO-PCI104-EMC4 Module Driver and Utility Installation
3-20
Function ID Function description Parameters
2 Set internal RTC time yyyy,MM,dd,hh,mm,ss
Where
yyyy is the year (2000 2099).
MM is the month (1-12).
dd is the day of the month (1-31).
hh is the hour of the day (0 -23).
mm is the minute (0-59).
ss is the second (0-59).
3 Display the RTC synchronization source. N/A
4 Set the RTC synchronization source. Source [0|2]
Where
0 is free run.
2 is port 1 input.
5 Display IRIG-B signal status.
Possible status are:
0–Normal
1–Off Line
2–Frame Error
3–Parity Error
Source [2]
Where
2 is port 1 input.
6 Display IRIG-B input parity check mode.
Possible modes are:
0–Even
1-Odd
2-None
Source [2]
Where
2 is port 1 input.
7 Set IRIG-B input parity check mode Source, Mode
Where
Source: 2 (port 1 input)
Mode: 0 (Even), 1 (Odd), 2 (None)
10 Display pulse per second width (ms). N/A
11 Set pulse per second width (ms). Width (0~999)
12 Display input signal type. port [0|1]
Where
1 is port 1 input.
13 Set input signal type. port, signal type, mode, inverse
Where
port 1 is “Port 1”
signal type 0 is TTL; 1 is “DIFF”
inverse 0 means do not inverse; 1
means inverse.
16 Display digital output. port
where 0 is “DO0”, 1 is “DO1”, 2 is “DO2”,
and 3 is “DO3
17 Set digital output. port, level
Where
port 0 is “DO0”, 1 is “DO1”, 2 is “DO2”,
and 3 is “DO3
level 0 is low and 1 is high
18 Display digital input. port
Where 0 is “DI0”, 1 is “DI1”, and 2 is “DI2”
NOTE
Function IDs 8, 9, 14, and 15 are not available for the DA-IRGB-4DIO-PCI-104-
EMC4 module, which does not
support the fiber input port.