14. Troubleshooting
14.1 Fault table
%|şùŒ |şń¼ áV¼ă¼®ź
The water does not
heat up and the ON/OFF
indicator does not il-
luminate.
The high limit safety cut-
out has responded.
Check the appliance and
remove the cause.
Press the reset button
(see diagram).
The high limit safety
cut-out has responded
because the controller
is faulty.
Replace the controller.
Press the reset button
(see diagram).
The flanged immersion
heater is faulty.
Replace the flanged im-
mersion heater.
The heat-up time is very
long and the ON/OFF in-
dicator illuminates.
The flanged immersion
heater is scaled up.
Descale the flanged im-
mersion heater.
The safety valve is drip-
ping and the ON/OFF
indicator does not il-
luminate.
The valve seat is con-
taminated.
Clean the valve seat.
High limit safety cut-out reset button
26_02_07_0150
ª Pull off the temperature selector and the rapid heat-up
button.
ª Undo the screws.
ª Remove the bottom cap.
ª Isolate the power cable.
2
1
26_02_07_0151
1 Reset button
2 High limit safety cut-out