Moxa MPC-2247X [62/64] Adf ac input power detect function

Moxa MPC-2240X [62/64] Adf ac input power detect function
MPC-2240 Hardware Manual UART Commands for Display Control
B-4
Send ETC to query elapsed time:
0x07 0xFF 0x45 0x54 0x43 0x00 0x1D
ACK 99999 hours
06 FF 45 54 43 05 19 39 39 39 39 39 E2
GMB: Glass Display Control - Minimum Brightness
This command is to set the minimum value limit for the brightness of touch keypad LED to make sure that the
LED indicators are still visible if they was previously adjusted down to a very low value. The range starts from
0x00 to 0x31 (0% - 100%). LEN=one byte.
Example
Command to set 30% Brightness.
0x07 0xFF 0x47 0x4D 0x42 0x01 0x22 0x10 0xEF
POT: Potentiometer Control
This command enables or disables the brightness keys (+/-). If the data and data checksum do not match, the
computer will return a NACK packet, and indicate the current control status in the data field (byte 8). LEN=one
byte.
0x00 Brightness +/Brightness - Key Disable
0xFF Brightness +/Brightness - Key Enable
Example
Disable the BR+/BR- Key.
0x07 0xFF 0x50 0x4F 0x54 0x01 0x05 0x00 0xFF
ACK
0x06 0xFF 0x50 0x4F 0x54 0x01 0x06 0x00 0xFF
SWI: Query the Scalar Board’s Firmware Version
This command returns the version of the scalar board’s firmware.
Example:
Query the Scalar Board’s Firmware Version
0x07 0xFF 0x53 0x57 0x49 0x00 0x06
SWK: Touch Keypad Firmware Version Query
This command returns the firmware version for the SavvyTouch display controls.
Example:
Query SavvyTouchFirmware Version
0x07 0xFF 0x53 0x57 0x4B 0x00 0x04
ADF: AC Input Power Detect Function
This default value of this function is OFF. If the MPC-2240 supports AC power input, users can turn on this
function to detect AC input power when the MPC-2240 has connected to the AC power. LEN=one byte.
0x00 AC Input Power Detect is OFF
0xFF AC Input Power Detect is ON
Example
Set “OFF”.
0x07 0xFF 0x41 0x44 0x46 0x01 0x2D 0x00 0xFF
ACK
0x06 0xFF 0x41 0x44 0x46 0x01 0x2E 0x00 0xFF