Moxa MPC-2247X [63/64] Ad query ac input power detect function status

Moxa MPC-2240X [63/64] Ad query ac input power detect function status
MPC-2240 Hardware Manual UART Commands for Display Control
B-5
AD?: Query AC Input Power Detect Function Status
If the MPC-2240 supports AC power input, users can use command is to query AC Input Power Detect Function
Status.
0x00 AC Input Power Detect is OFF
0xFF AC Input Power Detect is ON
Example
Send AD? command to Query AC Input Power Detect Function Status
0x07 0xFF 0x41 0x44 0x3F 0x00 0x35
ACK
0x06 0xFF 0x41 0x44 0x3F 0x01 0x35 0x00 0xFF
BLI: Brightness Control
This command is to set the panel brightness. Brightness range is from 0x00 to 0xFF. Default Brightness is 160.
LEN=one byte.
Example
Set brightness to 255(0xFF)
0x07 0xFF 0x42 0x4C 0x49 0x01 0x21 0xFF 0x00
ACK
0x06 0xFF 0x42 0x4C 0x49 0x01 0x22 0xFF 0x00
Query current brightness value
0x07 0xFF 0x42 0x4C 0x49 0x00 0x22
ACK
0x06 0xFF 0x42 0x4C 0x49 0x01 0x22 0xFF 0x00
DUF: Disable UART Command Function
Users can use this command to disable related command control. LEN=one byte.
DATA IDCHK Function description
0x00 0xFF Disable all command control
0x01 0xFE Disable BRI control
0x02 0xFD Disable BRL control
0x04 0xFB Disable BRM setting, returning the controls to factory default
0x08 0xF7 Disable BZZ control
0x10 0xEF Disable ETC control
0x20 0xDF Disable GMB control
0x40 0xBF Disable POT control
Example
Disable all command control
0x07 0xFF 0x44 0x55 0x46 0x01 0x19 0x00 0xFF
ACK
0x06 0xFF 0x44 0x55 0x46 0x01 0x1A 0x00 0xFF
NACK
0x15 0xFF 0x44 0x55 0x46 0x01 0x0B 0x00 0xFF
EMS: ECDIS Mode Select
For the ECDIS models, users can use this command to switch DAY, DUSK and NIGHT mode. LEN=one byte.
DATA IDCHK
DAY 0x00 0xFF
DUSK 0x01 0xFE
NIGHT 0x02 0xFD

Содержание