Moxa OnCell 5104-HSPA-T [14/67] Attention

Moxa OnCell 5104-HSPA-T [14/67] Attention
OnCell 5000 Series Getting Started
2-6
LED Indicators
The following table explains the LED indicators on the front panel of the OnCell 5000 Series:
Type Color LED Function
PWR 1
Green Activation of DC Power
Off Power is off, or power error condition exists.
PWR 2
Green Activation of DC Power
Off Power is off, or power error condition exists.
2G
Amber 2G is connected
Off 2G is disconnected
3G
Amber 3G is connected
Off 3G is disconnected
REG
Off Cannot register with cellular providers
Amber Registered with cellular provider
SIM1/2
Off SIM slot not in used
Amber
Static on: SIM inserted and PIN code correct in used normally.
Blinking slowly (1sec):SIM inserted and PIN code incorrect: blinking
Blinking slowly (0.5sec):No SIM inserted
WAN
Amber WAN port is connected
Off WAN port is not connected
Ready
Green
Steady on: Software Ready.
Blinking slowly (1 sec): The OnCell has been located by
Ready the OnCell Search Utility.
off Power is off, or is booting up.
Fault
Red
Steady on: Booting up, or IP fault.
Blinking slowly (1 sec): Cannot get an IP address from the DHCP server
off Power is off, or there is no error condition.
LAN 1-4
Green
Steady on: Software Ready.
Blinking slowly (1 sec): Data transmission
off Power is off, or is booting up.
Signal (3 LEDs) Green
Signal Level (at least 2 LEDs must illuminated for data
transmission)
ATTENTION
REG LED
:
OFF: Cannot register with cellular providers using 3G mode, due to the wrong PIN code, or no cellular
provider available. Signal LEDs will also be off.
ON: Registered with cellular provider.
3G LED
:
OFF: Cannot register with cellular providers using UMTS/HSPA mode due to the wrong PIN code, no
cellular provider available, wrong APN, or wrong username/password.
ON: Registered with cellular provider using UMTS/HSPA mode. UMTS or HSPA/Signal LEDs will be on.
Reset Button
Press and hold the Reset button for 5 sec to load factory defaults: Use a pointed object, such as a straightened
paper clip or toothpick to press the reset button. This will cause the Ready LED to blink on and off. The factory
defaults will be loaded once the Ready LED stops blinking (default LAN IP: 192.168.127.254).