Moxa VPort P06-1MP-M12-CAM42 [40/65] Http event server

Moxa VPort P06-1MP-M12-CAM42 [40/65] Http event server
VPort P06-1MP-M12 System Configuration
4-18
HTTP Event Server
The VPort can send the customized alarm actions and messages to the HTTP Event Servers, which allows users
to design a customized alarm system.
Setting Description Factory Default
Host Name User-defined name for identification Blank
Server 1, 2, 3, 4 The servers URL address with complete CGI commands Ex.
http:// http event server:Port/CGI_Name
Blank
User name The account name for accessing the HTTP server Blank
Password The password for accessing the HTTP server Blank
Once the Http Alarm is triggered, the VPort will send the following HTTP commands to the HTTP event servers.
GET CGI_Name?address=<Hostname or IP Address>&[Custom CGI] HTTP/1.0\r\n
User-Agent: IP camera V1.1\r\n
[Authorization: Basic <Buse64(username:password)>\r\n]
Host: <HTTP Server IP Address>\r\n
Connection: Keep-Alive\r\n
\r\n