Aten CS261 [10/22] Formulas

Aten CS261 [10/22] Formulas
CS261 RS-232 Control Tool
10
Timeout
The Timeout command allows you to set the timeout period. Use the Formula
- to set Parameters - to create a Command.
Formulas:
Command + Control + [Enter]
Parameters:
Timeout Commands
Some available formulas for Timeout commands are as follows:
Command + Control + [Enter]
To set the timeout period to 5 seconds, type the following:
timeout t1 [Enter]
To set the timeout period to 255 seconds, type the following:
timeout t4 [Enter]
Note: 1. Each command string can be separated with a space.
2. The default timeout setting is t1.
3. The ASCII code for Enter is 0x0D0A.
Command Description
timeout Timeout Period
Control Description
tx Set timeout period
x=1, timeout period is 5 seconds
x=2, timeout period is 60 seconds
x=3, timeout period is 120 seconds
x=4, timeout period is 255 seconds
Enter Description
Enter Enter and send out command