Aten CS261 [7/22] Formula

Aten CS261 [7/22] Formula
CS261 RS-232 Control Tool
7
Switch Operation
The switch port command allows you to switch between computers connected
to the CS261’s ports. Use the Formula - to set Parameters - to create a
Command.
Formula:
Command + Input Command + [Enter]
Parameters:
Switch Console Commands
Some available formulas for the Switch Console commands are as follows:
Command + Input Command + [Enter]
To switch to console 2, type the following:
sw p2 [Enter]
To switch to auto mode, type the following:
sw auto [Enter]
Note: 1. Each command string can be separated with a space.
2. The default console selected is 1.
3. The ASCII code for Enter is 0x0D0A.
Command Description
sw Switch Operation Command
Input Command Description
auto Select auto mode
px Input console number manually,
x= 1~2 (Default: 1)
private Select private mode.
Privileged user depends on DIP
switch pin 4 setting.
Enter Description
Enter Enter and send out command