Adaptec ASR-8405 SGL — управление SSD в maxCache: добавление и удаление дисков [91/117]

Adaptec ASR-8405 SGL [91/117] Modifying your controller s configuration
maxCache-compatible SSDs, refer to the Adaptec Web site at
www.adaptec.com/compatibility.
To add a SSD to the maxCache pool or to remove a SSD from the pool:
1. Select Manage MaxCache Pool from the Logical Device Conguration menu.
All supported SSDs are displayed.
Note: Uninitialized SSDs may not appear in the list; see Initializing Disk Drives on
page 89 for more information.
2. Using the arrow keys, select a SSD from the list.
3. Press Ins to add the SSD to the maxCache pool.
4. To remove a SSD from the pool, press the right arrow to switch windows, use the arrow keys to
select a SSD, then press Del.
5. Press Enter to save your changes and return to the main menu.
Using the ARC Utility to Modify Controller Settings
The ARC Controller Settings tool allows you to modify the settings of your controller and the disk drives
connected to it.
Opening the Controller Settings Tool
To open the ARC Controller Settings tool, start the ARC utility (see Running the ARC Utility on page 86),
select Controller Settings from the ARC main menu, then press Enter.
Follow the on-screen instructions to modify the settings of your controller and connected disk drives,
as needed.
Applying Changes and Exiting
1. To exit the Controller Settings tool, press Esc until you are prompted to exit.
If you modied any settings, you are prompted to save the changes before you exit.
2. Select Yes to exit, then press any key to restart your computer.
Any changes you made take effect after the computer restarts.
Modifying Your Controllers Conguration
Note: Default controller settings are suitable for most computers. We recommend
that you do not change the default setting.
To modify your controller's basic settings, select Controller Conguration from the main Controller
Settings menu.
To modify your controller's power management settings, select Advanced Conguration.
Some options may not be available for your controller.
General Controller Settings
Note: Default settings are shown in bold type.
DescriptionOption
When set to Enable All, write cache is enabled on all disk drives on the controller.
(Enabling the write cache overrides any individual drive settings in maxView S
Drive's Write Cache (uEFI only)
torage Manager or the BIOS.) When set to Disable All, write cache is not used on
the disk drives. When set to Drive Specic, write cache is enabled/disabled on a
per-drive basis in maxView Storage Manager or the BIOS. Default is Disable All.
Caution: When write cache is enabled, there is a slight
possibility of data loss or corruption during a power failure.
91Proprietary and Condential to PMC-Sierra, Inc.