Castel MAC HC 40 NTV [11/18] Menu 2 change setpoint
![Castel MAC HC 40 NTV [11/18] Menu 2 change setpoint](/views2/1318627/page11/bgb.png)
11
GB
When the language required is displayed, press
the
ENTER
BUTTON; the controller requests
a second confirmation by displaying EXIT or
CONFIRM.
Press the button to confirm or the
ENTER
button to exit and return to the initial mask.
4.3 Date and time setting
Press the MENU button and with buttons
or
go to MENU 8 SET CLOCK; press
ENTER
and the date and time will be displayed with
the first digit of the day blinking. Modify the digit
with buttons
or and confirm the value
with the
ENTER
button, the new value is
acquired and the month digit blinks next. Repeat
in succession the procedure until the seconds
value is reached , and press the
ENTER
but-
ton. The successful acquisition of the values will
be signalled by the flashing date and time.
4.4 Display and setting of the set point
Press the MENU button and with buttons
or
go to the MENU 2 CHANGE mask
SET POINT; press the
ENTER
button; the
temperature set and the temperature to modify is
displayed. Modify the NEW SET temperature
using the button to increase the value by N
degrees and button to decrease the value by
N degrees To memorise the new temperature set,
press the
ENTER
button. The new value will
flash to confirm that it has been memorised.
4.5 Humidity adjustment
(on HC20C only)
Press the MENU and use the
or
buttons
to open the MENU 3 - CHANGE HUMIDITY win-
dow; press ENTER; the current humidity level and
the new one to be set will be shown. Use the
or
buttons to change the humidity NEW RH%
and press ENTER to confirm. The value will blink
to confirm it has been accepted.
Humidity values can be varied within an accepted
range of 40% to 90%.
4.6 Door microswitch function
The controller signals the opening of the door and
shows the following mask on the display.
The evaporator fans will stop every time one of
the doors opens and will start again when it clos-
es again. If the door remains open for more than
five minutes, the signalling buzzer is activated
and the fan of the evaporator will start up again as
if it were closed.
4.7 Recirculation fan in continuous opera-
tion (Function not available for model
HC20NT/2 HC20NTV HC20BTV HC20BTV/2
HC40NTV HC40BTV)
Keep the button pressed on ON to activate
the recirculation fan. In this mode the internal fan
remains on in continuous mode independently of
the compressor function.
Press the same button again to deactivate it.
4.8 Restore menu
If the electronic card crashes or because of peaks
or losses of voltage the programming data is lost,
it is possible for the user to load the factoring set-
tings.
Press the MENU button, use buttons
or
to go to the restore menu and press the
ENTER
button; in this way the cabinet model and the
programming number loaded is shown.
Press
ENTER
again and confirm with the but-
ton ; the card turns off and the factory settings
are restored.
DOOR OPEN >>OK
Cell -21°C
NEW SET: -15°C
CURRENT: -15°C
Menu 2
CHANGE SETPOINT
Date: 12/04/03
Time: 11:54:23
Содержание
- Conservation cabinets 1
- Highcontrol 1
- Instructions for use 1
- General documentation 4
- General information 4
- Out fig for the stainless steel versions wear protective gloves when han dling the packaging and the wooden base 4
- Installation 5
- Accessories 8
- Hc 20 c nt ntv ntb btv fx 8
- Hc 20 nt 2 bt 2 btv 2 8
- Hc 40 btv ntb ntv 8
- Operating spaces 8
- Positioning 8
- Technical characteristics 9
- Date 12 04 03 time 11 54 23 11
- Hc20nt 2 hc20ntv hc20btv hc20btv 2 hc40ntv hc40btv 11
- Menu 2 change setpoint 11
- New set 15 c current 15 c 11
- Ok cell 21 c 11
- Call service 12
- Defrosting management 12
- F18 defr time s 19 02 02 06 09 12
- Menu 4 defrosting 12
- Ok cell 10 5 c 12
- Ok cell 18 c 12
- Al 27 high temp duration 015 13
- Al 27 high temp max temp 25 c 13
- Al 27 high temp s 18 03 02 12 29 13
- Alarm detected cell 24 0 c 13
- Ht cell 18 c 13
- Lt cell 24 c 13
- Management of the alarms detected and turning them off 13
- Al 26 black out b 15 03 02 10 22 14
- Al 26 black out max temp 12 c 14
- Al 26 black out s 15 03 02 10 01 14
- Alarm detected cell 24 0 c 14
- Button the cancellation is automatic when the mal function is rectified the alarm is however logged in the alarm menu 14
- Contact an authorised tecnomac centre in the case of a serious alarm 14
- Example of a blackout alarm 14
- Important 14
- In the case of high low temperature alarms before being registered a prealarm time of sixty minutes is calculated at the end of this time the controller logs the alarm in the alarm log and shows the following mask on the display 14
- Malfunctioning message they jeopardise machine operation call the service message display cause cancellation 14
- Serious alarm list serious alarms can determine the incorrect functioning of the conservator the display is the same as that described for the alarms and the signalling buzzer is acti vated to silence the buzzer press the 14
- To eliminate the indication go into the alarm log as shown in the paragraph above 14
- Alarm detected fixed logging of a remove the cause of the alarm alarm in the log and enter into menu 1 alarm log to reset the controller 15
- Ht fixed high temp prealarm automatic rectification 15
- List of any other malfunctions that cannot be signalled 15
- Lt fixed low temp prealarm automatic rectification 15
- Set clock loss of clock data set clock data 15
- Signalling messages they do not jeopardise the functioning of the machine message display cause cancellation 15
- Ordinary maintenance 16
Похожие устройства
- Castel MAC TC 60 N Инструкция по эксплуатации
- Castel MAC HC 20 BT Инструкция по эксплуатации
- Castel MAC HC 20 NTB Инструкция по эксплуатации
- Steno PL7B Инструкция по эксплуатации
- ТОРГМАШ УКМ-14 Инструкция по эксплуатации
- ТОРГМАШ УКМ-14 Сертификат
- ТОРГМАШ УКМ-14 Каталог оборудования ТОРГМАШ
- Pavoni MINITEMPER Инструкция по эксплуатации
- Pavoni MINITEMPER Каталог оборудования Pavoni (англ.)
- Castel MAC HC 20 C Инструкция по эксплуатации
- Talsa Н26pa Инструкция по эксплуатации
- Talsa H42pas Инструкция по эксплуатации
- Talsa Н31pas Инструкция по эксплуатации
- Talsa Н15pa Инструкция по эксплуатации
- Helia Smoker 48 Инструкция по эксплуатации
- Helia Smoker 48 Рецепты копчения
- Helia Smoker 24 Инструкция по эксплуатации
- Helia Smoker 24 Рецепты копчения
- CAS CNW-460 Инструкция по эксплуатации
- CAS СNW-520 Инструкция по эксплуатации