Castel MAC HC 40 NTV [9/18] Technical characteristics
![Castel MAC HC 40 NTV [9/18] Technical characteristics](/views2/1318627/page9/bg9.png)
9
GB
3. TECHNICAL CHARACTERISTICS
Capacity in litres
Temperature °C
Single phase electric power supply
R404a refrigerant
Refrigerating capacity (*)
Input power (*)
Net weight, kg
Width
Depth
Height
Width
Depth
Height
Extractable rack, pitch mm.
Runners supplied, no. of couples
Gastronorm shelves nr.
Shelf sizes mm.
Anti-tipping guides, no. of couples
Humidity HR%
Outer
dimensions
mm.
Internal
dimensions
mm.
(*) Evaporation temperature -10 °C ∅ mm. 120x165x360
(**) Evaporation temperature -28 °C
Capacity in litres
Temperature °C
Single phase electric power supply
R404a refrigerant
Refrigerating capacity (*)
Input power (*)
Net weight, kg
Width
Depth
Height
Width
Depth
Height
Extractable rack, pitch mm.
Runners supplied, no. of couples
Gastronorm shelves nr.
Shelf sizes mm.
Anti-tipping guides, no. of couples
Ice cream tub capacity. No.
Outer
dimensions
mm.
Internal
dimensions
mm.
HC20 BTV
HC20 BTV/2
620
-10/-24
220-230V/50HZ
R404a
450 W
620 W
148
710
890
1975÷2035
590
720
1300
35
—
5
530x650
5
—
HC40 BTV
1350
-10/-24
220-230V/50HZ
R404a
1100 W
1200 W
260
1440
890
1975÷2035
1320
720
1300
35
—
10
530x650
10
—
HC20 NT
HC NT/2
620 (600 NT/2)
+8/-8 (+8/-4 NT/2)
220-230V/50HZ
R134a
350 W (*)
310 W
145 (150 NT/2)
710
890
1975÷2035
590
720
1450 (1300 NT/2)
35
—
5 (6 NT/2)
530x650
5 (6 NT/2)
—
HC20 BT
HC20 BT/2
620
-15/-28
220-230V/50HZ
R404a
450 W (**)
600 W
155
710
890
1975÷2035
590
720
1450
35
—
5
530x650
5
50∅ (58∅ BT/2)
HC20 NTV
620
+8/-2
220-230V/50HZ
R134a
350 W
380 W
141
710
890
1975÷2035
590
720
1450
35
—
5
530x650
5
HC20 C
620
+4/+15
220-230V/50HZ
R404a
475 W
450 W
148
710
890
1975÷2035
590
720
1300
35
—
—
650x450
5
40% / 90%
HC40 NTV
1350
+8/-2
220-230V/50HZ
R134a
660 W
600 W
250
1440
890
1975÷2035
1320
720
1450
35
—
10
530x650
10
HC20 NTB
620
+10/-2
220-230V/50HZ
R404a
475 W
450 W
142
710
890
1975÷2035
590
720
1300
35
—
5
530x650
5
HC40 NTB
1350
+10/-2
220-230V/50HZ
R134a
660 W
620 W
250
1440
890
1975÷2035
1320
720
1450
35
—
10
530x650
10
Содержание
- Conservation cabinets 1
- Highcontrol 1
- Instructions for use 1
- General documentation 4
- General information 4
- Out fig for the stainless steel versions wear protective gloves when han dling the packaging and the wooden base 4
- Installation 5
- Accessories 8
- Hc 20 c nt ntv ntb btv fx 8
- Hc 20 nt 2 bt 2 btv 2 8
- Hc 40 btv ntb ntv 8
- Operating spaces 8
- Positioning 8
- Technical characteristics 9
- Date 12 04 03 time 11 54 23 11
- Hc20nt 2 hc20ntv hc20btv hc20btv 2 hc40ntv hc40btv 11
- Menu 2 change setpoint 11
- New set 15 c current 15 c 11
- Ok cell 21 c 11
- Call service 12
- Defrosting management 12
- F18 defr time s 19 02 02 06 09 12
- Menu 4 defrosting 12
- Ok cell 10 5 c 12
- Ok cell 18 c 12
- Al 27 high temp duration 015 13
- Al 27 high temp max temp 25 c 13
- Al 27 high temp s 18 03 02 12 29 13
- Alarm detected cell 24 0 c 13
- Ht cell 18 c 13
- Lt cell 24 c 13
- Management of the alarms detected and turning them off 13
- Al 26 black out b 15 03 02 10 22 14
- Al 26 black out max temp 12 c 14
- Al 26 black out s 15 03 02 10 01 14
- Alarm detected cell 24 0 c 14
- Button the cancellation is automatic when the mal function is rectified the alarm is however logged in the alarm menu 14
- Contact an authorised tecnomac centre in the case of a serious alarm 14
- Example of a blackout alarm 14
- Important 14
- In the case of high low temperature alarms before being registered a prealarm time of sixty minutes is calculated at the end of this time the controller logs the alarm in the alarm log and shows the following mask on the display 14
- Malfunctioning message they jeopardise machine operation call the service message display cause cancellation 14
- Serious alarm list serious alarms can determine the incorrect functioning of the conservator the display is the same as that described for the alarms and the signalling buzzer is acti vated to silence the buzzer press the 14
- To eliminate the indication go into the alarm log as shown in the paragraph above 14
- Alarm detected fixed logging of a remove the cause of the alarm alarm in the log and enter into menu 1 alarm log to reset the controller 15
- Ht fixed high temp prealarm automatic rectification 15
- List of any other malfunctions that cannot be signalled 15
- Lt fixed low temp prealarm automatic rectification 15
- Set clock loss of clock data set clock data 15
- Signalling messages they do not jeopardise the functioning of the machine message display cause cancellation 15
- Ordinary maintenance 16
Похожие устройства
- Castel MAC TC 60 N Инструкция по эксплуатации
- Castel MAC HC 20 BT Инструкция по эксплуатации
- Castel MAC HC 20 NTB Инструкция по эксплуатации
- Steno PL7B Инструкция по эксплуатации
- ТОРГМАШ УКМ-14 Инструкция по эксплуатации
- ТОРГМАШ УКМ-14 Сертификат
- ТОРГМАШ УКМ-14 Каталог оборудования ТОРГМАШ
- Pavoni MINITEMPER Инструкция по эксплуатации
- Pavoni MINITEMPER Каталог оборудования Pavoni (англ.)
- Castel MAC HC 20 C Инструкция по эксплуатации
- Talsa Н26pa Инструкция по эксплуатации
- Talsa H42pas Инструкция по эксплуатации
- Talsa Н31pas Инструкция по эксплуатации
- Talsa Н15pa Инструкция по эксплуатации
- Helia Smoker 48 Инструкция по эксплуатации
- Helia Smoker 48 Рецепты копчения
- Helia Smoker 24 Инструкция по эксплуатации
- Helia Smoker 24 Рецепты копчения
- CAS CNW-460 Инструкция по эксплуатации
- CAS СNW-520 Инструкция по эксплуатации