Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA [11/34] Function selection
![Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA [11/34] Function selection](/views2/1324275/page11/bgb.png)
11
8. Function Selection
[Function selection flowchart]
Setting language (English)
OFF
on1
on2
OFF
ON
OFF
ON
OFF
OFF
CALL-
ON
OFF
ON
OFF
°C
°F
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
F
E
G
C
D
H
B
A
I
G
G
G
G
G
G
E
E
G
G
G
G
G
E
G
E
G
G
G
G
G
G
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
English
Germany
Spanish
Russian
Italy
Chinese
French
Japanese
*
*
Hold down the E button and press the D button for 2 seconds.
Hold down the E button and press the D button for 2 seconds.
Remote controller function selection mode
E Press the operation mode button.
G Press the TIMER MENU button.
D Press the TIMER ON/OFF button.
Item1 Item2
Dot display
Item3
Room air temperature is not displayed.
One of “Automatic cooling” and “Automatic heating” is displayed
under the automatic mode is running. (Initial setting value)
Only “Automatic” is displayed under the automatic mode.
Normal display
(Display when the air condition is not running)
Change
Language
Function
selection
Mode
selection
Display
mode setting
Operation lock setting is not used.
(Initial setting value)
Operation lock setting is except On/Off button.
Operation lock setting is All buttons.
The automatic mode is displayed when the operation mode is
selected. (Initial setting value)
The automatic mode is not displayed when the operation mode
is selected.
The temperature range limit is not active. (Initial setting value)
The temperature range can be changed on cooling/dry mode.
The temperature range can be changed on heating mode.
The temperature range can be changed on automatic mode.
The remote controller will be the main controller. (Initial setting value)
The remote controller will be the sub controller.
The clock function can be used. (Initial setting value)
The clock function can not be used.
Weekly timer can be used. (Initial setting value)
Auto off timer can be used.
Simple timer can be used.
Timer mode can not be used.
The set contact numbers are not displayed in case of error.
(Initial setting value)
The set contact numbers are displayed in case of error.
The temperature unit °C is used. (Initial setting value)
The temperature unit °F is used.
Room air temperature is displayed. (Initial setting value)
*) For this model, this function is not available.
KB79H133H04_en.pm6 08.6.23, 2:48 PM11
Содержание
- Air conditioners 1
- Bedieningshandleiding 1
- Bedienungshandbuch 1
- Driftsmanual 1
- E xeipi io o h iøn xph eø 1
- Fletme elk tabi 1
- Istruzioni di funzionamento 1
- Manual de instrucciones 1
- Manual de operação 1
- Manuel d utilisation 1
- Operation manual 1
- Sez kd25 kd35 kd50 kd60 kd71va 1
- Руководство по эксплуатации 1
- Contents 2
- Disposing of the unit 2
- Indicates a part which must be grounded 2
- Other functions 9 8 function selection 10 9 care and cleaning 14 10 trouble shooting 15 11 installation relocation and inspection 16 12 specifications 17 2
- Parts names 2
- Safety precautions 2
- Safety precautions 2 2 parts names 2 3 screen configuration 4 4 setting the day of the week and time 4 5 operation 5 6 timer 6 2
- Symbols used in the illustrations 2
- Symbols used in the text 2
- Display section 3
- Operation section 3
- Parts names 3
- Parts names 4
- Screen configuration 4
- Setting the day of the week and time 4
- 4 5 8 7 1 5
- Description of auto restart function 5
- Fan speed setting 5
- Information for multi system air conditioner outdoor unit mxz series 5
- Mode select 5
- Operation 5
- Temperature setting 5
- Turning on off 5
- For wired remote controller 6
- Operation 6
- Ventillation 6
- Weekly timer 6
- Simple timer 7
- Auto off timer 8
- Locking the remote controller buttons operation function limit controller 9
- Other functions 9
- Other indications 9
- Alternating display 10
- Error code 10
- Error code indoor unit no 10
- Error codes indication 10
- Function selection 10
- Function selection of remote controller 10
- G if the on lamp and error code are both flashing this means that the air conditioner is out of order and operation has been stopped and cannot resume take note of the indicated unit number and error code then switch off the power to the air conditioner and call your dealer or servicer g if only the error code is flashing while the on lamp remains lit opera tion is continuing but there may be a problem with the system in this case you should note down the error code and then call your dealer or servicer for advice if you have entered contact number to be called in the event of a problem push the check button to display it on the screen you can set this up under function selection of remote controller for infor mation refer to section 8 10
- If you have entered contact number to be called in the event of a prob lem the screen displays this number you can set this up under func tion selection of remote controller for information refer to section 8 10
- Indoor unit s refrigerant address 10
- On lamp flashing 10
- Other functions 10
- The setting of the following remote controller functions can be changed using the remote controller function selection mode change the setting when needed 10
- When the check button is pressed 10
- Function selection 11
- Function selection flowchart setting language english 11
- Function selection 12
- Dot display table 13
- Function selection 13
- Selecting language english germany spanish russian italy chinese french japanese 13
- Care and cleaning 14
- Function selection 14
- Trouble shooting 15
- Installation relocation and inspection 16
- Trouble shooting 16
- Installation relocation and inspection 17
- Specifications 17
- Другие функции 171 8 выбор функции 172 9 очистка и уход 176 10 устранение неисправностей 177 11 установка перемещение и проверка 178 12 спецификации 179 18
- Меры предосторожности 18
- Меры предосторожности 164 2 наименования частей 164 3 конфигурация экрана 166 4 установка дня недели или времени 166 5 работа 167 6 таймер 168 18
- Наименования частей 18
- Прекращение эксплуатации блока 18
- Символы используемые в иллюстрациях 18
- Символы используемые в тексте 18
- Содержание 18
- Индикатор направления воздушного потока вверх вниз 19
- Индикатор скорости вентилятора 19
- Наименования частей 19
- Рабочий раздел 19
- Секция дисплея 19
- Конфигурация экрана 20
- Наименования частей 20
- Установка дня недели или времени 20
- Включение выключение 21
- Выбор режима 21
- Информация для мультисистемного кондиционера воздуха наружный блок модели mxz 21
- Описание auto restart function функция автоматического перезапуска 21
- Работа 21
- Установка скорости вентилятора 21
- Установка температуры 21
- Вентиляция 22
- Для проводного пульта дистанционного управления 22
- Недельный таймер 22
- Работа 22
- Таймер 22
- Обычный таймер 23
- Таймер 23
- Таймер 24
- On off 25
- Блокировка кнопок пульта дистанционного управления контроллер ограничения рабочей функции 25
- Другие функции 25
- Прочие индикации 25
- Таймер 25
- On off 26
- Выбор функции 26
- Выбор функции пульта дистанционного управления 26
- Другие функции 26
- Индикация кодов ошибок 26
- Выбор функции 27
- Выбор функции 28
- Выбор функции 29
- Выбор функции 30
- Очистка и уход 30
- Устранение неисправностей 31
- Установка перемещение и проверка 32
- Устранение неисправностей 32
- Спецификации 33
- Установка перемещение и проверка 33
Похожие устройства
- Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA Брошюра
- Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA Руководство по установке
- Mitsubishi Electric SEZ-KD50VAQ / SUZ-KA50VA Инструкция по эксплуатации
- Mitsubishi Electric SEZ-KD50VAQ / SUZ-KA50VA Брошюра
- Mitsubishi Electric SEZ-KD50VAQ / SUZ-KA50VA Руководство по установке
- Mitsubishi Electric SLZ-KA50VAL / SUZ-KA50VA Инструкция по эксплуатации
- Mitsubishi Electric SLZ-KA50VAL / SUZ-KA50VA Брошюра
- Mitsubishi Electric SLZ-KA50VAL / SUZ-KA50VA Руководство по установке
- Mitsubishi Electric MSZ-HJ35VA / MUZ-HJ35VA Инструкция по эксплуатации
- Mitsubishi Electric MSZ-HJ35VA / MUZ-HJ35VA Брошюра
- Mitsubishi Electric MSZ-HJ35VA / MUZ-HJ35VA Руководство по установке
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Инструкция по эксплуатации
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Брошюра
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Руководство по установке
- Mitsubishi Electric MJ-E16PX Инструкция по эксплуатации
- GE Monogram ZISS 480 NX SS Инструкция по эксплуатации
- GE Monogram ZISS 480 NX SS Брошюра
- GE Monogram ZISP 480 DX SS Инструкция по эксплуатации
- GE Monogram ZISP 480 DX SS Брошюра
- Mitsubishi Electric SEZ-KD25VAQ / SUZ-KA25VA Инструкция по эксплуатации
Скачать
Случайные обсуждения