Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA [8/34] Auto off timer
![Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA [8/34] Auto off timer](/views2/1324275/page8/bg8.png)
8
6. Timer
7. After completing steps 3 to 6 above, press the Filter button 4 to lock
in the value.
Note:
Your new settings will be cancelled if you press the Mode (Return) button 2
before pressing the Filter
button 4.
8. Press the Mode (Return) button 2 to return to the standard control
screen.
9. Press the Timer On/Off button 9 to start the timer countdown. When the
timer is running, the timer value is visible on the display. Be sure that the
timer value is visible and appropriate.
<Viewing the Current Simple Timer Settings>
TIMER ON
OFF
Hr
AFTER
SIMPLE
1
6
5
1. Be sure that the simple timer indicator is visible on the screen (at 1).
2. Press the Timer Menu button B, so that the “Monitor” appears on the
screen (at 5).
• If the ON or OFF simple timer is running, the current timer value will
appear at 6.
• If ON and OFF values have both been set, the two values appear
alternately.
3. Press the Mode (Return) button 2 to close the monitor display and return
to the standard control screen.
<To Turn Off the Simple Timer...>
Press the Timer On/Off button 9 so that the timer setting no longer ap-
pears on the screen (at 7).
Timer Setting
˚C
˚C
SIMPLE
7
˚C
˚C
ONHr
AFTER
SIMPLE
7
<To Turn On the Simple Timer...>
Press the Timer On/Off button 9 so that the timer setting becomes visible
at 7.
Examples
If ON and OFF times have both been set at the simple timer, operation and
display are as indicated below.
Example 1:
Start the timer, with ON time set sooner than OFF time
ON Setting: 3 hours
OFF Setting: 7 hours
ONHr
AFTER
SIMPLE
˚C
˚C
OFF
Hr
AFTER
SIMPLE
SIMPLE
˚C
˚C
OFF
Hr
AFTER
SIMPLE
ONHr
AFTER
SIMPLE
▲
▲
▲
At 3 hours after timer start
Display changes to show the timer’s OFF set-
ting (hours remaining to OFF).
The time displayed is OFF setting (7 hours) –
ON setting (3 hours) = 4 hours.
At Timer Start
Display shows the timer’s ON setting (hours
remaining to ON).
At 7 hours after timer start
The air conditioner goes off, and will remain off
until someone restarts it.
˚C
˚C
SIMPLE
▲
At 2 hours after timer start
Display changes to show the timer’s ON setting
(hours remaining to ON).
The time displayed is ON setting (5 hours) –
OFF setting (2 hours) = 3 hours.
At Timer Start
Display shows the timer’s OFF setting (hours
remaining to OFF).
At 5 hours after timer start
The air conditioner comes on, and will continue
to run until someone turns it off.
6.1.3. Auto Off Timer
■ This timer begins countdown when the air conditioner starts, and shuts
the air conditioner off when the set time has elapsed.
■ Available settings run from 30 minutes to 4 hours, in 30-minute intervals.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same time.
*2. The Auto Off timer will not operate when any of the following conditions is
in effect.
The timer is off; the system is in malfunction state; a test run is in progress;
the remote controller is undergoing self-check or remote controller check;
the user is in the process of selecting a function; the user is in the process
of setting the timer; the system is under central control. (Under these con-
ditions, On/Off operation is prohibited.)
AFTER OFF
AUTO OFF
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK DAY
MONITOR/SET
CLOCK
ON/OFF
2A9
4
B
AFTER OFF
AUTO OFF
3
1
2
Timer Setting
<How to Set the Auto Off Timer>
1. Be sure that you are at a standard control screen, and that the Auto Off
timer indicator is visible in the display (at 1).
When something other than the Auto Off Timer is displayed, set it to
AUTO OFF TIMER using the function selection of remote controller (see
8.[4]–3 (3)) timer function setting.
2. Hold down the Timer Menu button B for 3 seconds, so that the “Set Up”
appears on the screen (at 2).
(Note that each press of the button toggles the display between “Set Up”
and “Monitor”.)
3. Press the appropriate Set Time button A as necessary to set the OFF
time (at 3).
4. Press the Filter button 4 to lock in the setting.
Note:
Your entry will be cancelled if you press the Mode (Return) button 2 before
pressing the Filter
button 4.
5. Press the Mode (Return) button 2 to complete the setting procedure and
return to the standard control screen.
6. If the air conditioner is already running, the timer starts countdown
immediately. Be sure to check that the timer setting appears cor-
rectly on the display.
Example 2:
Start the timer, with OFF time is sooner than ON time
ON Setting: 5 hours
OFF Setting: 2 hours
KB79H133H04_en.pm6 08.6.23, 2:48 PM8
Содержание
- Air conditioners 1
- Bedieningshandleiding 1
- Bedienungshandbuch 1
- Driftsmanual 1
- E xeipi io o h iøn xph eø 1
- Fletme elk tabi 1
- Istruzioni di funzionamento 1
- Manual de instrucciones 1
- Manual de operação 1
- Manuel d utilisation 1
- Operation manual 1
- Sez kd25 kd35 kd50 kd60 kd71va 1
- Руководство по эксплуатации 1
- Contents 2
- Disposing of the unit 2
- Indicates a part which must be grounded 2
- Other functions 9 8 function selection 10 9 care and cleaning 14 10 trouble shooting 15 11 installation relocation and inspection 16 12 specifications 17 2
- Parts names 2
- Safety precautions 2
- Safety precautions 2 2 parts names 2 3 screen configuration 4 4 setting the day of the week and time 4 5 operation 5 6 timer 6 2
- Symbols used in the illustrations 2
- Symbols used in the text 2
- Display section 3
- Operation section 3
- Parts names 3
- Parts names 4
- Screen configuration 4
- Setting the day of the week and time 4
- 4 5 8 7 1 5
- Description of auto restart function 5
- Fan speed setting 5
- Information for multi system air conditioner outdoor unit mxz series 5
- Mode select 5
- Operation 5
- Temperature setting 5
- Turning on off 5
- For wired remote controller 6
- Operation 6
- Ventillation 6
- Weekly timer 6
- Simple timer 7
- Auto off timer 8
- Locking the remote controller buttons operation function limit controller 9
- Other functions 9
- Other indications 9
- Alternating display 10
- Error code 10
- Error code indoor unit no 10
- Error codes indication 10
- Function selection 10
- Function selection of remote controller 10
- G if the on lamp and error code are both flashing this means that the air conditioner is out of order and operation has been stopped and cannot resume take note of the indicated unit number and error code then switch off the power to the air conditioner and call your dealer or servicer g if only the error code is flashing while the on lamp remains lit opera tion is continuing but there may be a problem with the system in this case you should note down the error code and then call your dealer or servicer for advice if you have entered contact number to be called in the event of a problem push the check button to display it on the screen you can set this up under function selection of remote controller for infor mation refer to section 8 10
- If you have entered contact number to be called in the event of a prob lem the screen displays this number you can set this up under func tion selection of remote controller for information refer to section 8 10
- Indoor unit s refrigerant address 10
- On lamp flashing 10
- Other functions 10
- The setting of the following remote controller functions can be changed using the remote controller function selection mode change the setting when needed 10
- When the check button is pressed 10
- Function selection 11
- Function selection flowchart setting language english 11
- Function selection 12
- Dot display table 13
- Function selection 13
- Selecting language english germany spanish russian italy chinese french japanese 13
- Care and cleaning 14
- Function selection 14
- Trouble shooting 15
- Installation relocation and inspection 16
- Trouble shooting 16
- Installation relocation and inspection 17
- Specifications 17
- Другие функции 171 8 выбор функции 172 9 очистка и уход 176 10 устранение неисправностей 177 11 установка перемещение и проверка 178 12 спецификации 179 18
- Меры предосторожности 18
- Меры предосторожности 164 2 наименования частей 164 3 конфигурация экрана 166 4 установка дня недели или времени 166 5 работа 167 6 таймер 168 18
- Наименования частей 18
- Прекращение эксплуатации блока 18
- Символы используемые в иллюстрациях 18
- Символы используемые в тексте 18
- Содержание 18
- Индикатор направления воздушного потока вверх вниз 19
- Индикатор скорости вентилятора 19
- Наименования частей 19
- Рабочий раздел 19
- Секция дисплея 19
- Конфигурация экрана 20
- Наименования частей 20
- Установка дня недели или времени 20
- Включение выключение 21
- Выбор режима 21
- Информация для мультисистемного кондиционера воздуха наружный блок модели mxz 21
- Описание auto restart function функция автоматического перезапуска 21
- Работа 21
- Установка скорости вентилятора 21
- Установка температуры 21
- Вентиляция 22
- Для проводного пульта дистанционного управления 22
- Недельный таймер 22
- Работа 22
- Таймер 22
- Обычный таймер 23
- Таймер 23
- Таймер 24
- On off 25
- Блокировка кнопок пульта дистанционного управления контроллер ограничения рабочей функции 25
- Другие функции 25
- Прочие индикации 25
- Таймер 25
- On off 26
- Выбор функции 26
- Выбор функции пульта дистанционного управления 26
- Другие функции 26
- Индикация кодов ошибок 26
- Выбор функции 27
- Выбор функции 28
- Выбор функции 29
- Выбор функции 30
- Очистка и уход 30
- Устранение неисправностей 31
- Установка перемещение и проверка 32
- Устранение неисправностей 32
- Спецификации 33
- Установка перемещение и проверка 33
Похожие устройства
- Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA Брошюра
- Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA Руководство по установке
- Mitsubishi Electric SEZ-KD50VAQ / SUZ-KA50VA Инструкция по эксплуатации
- Mitsubishi Electric SEZ-KD50VAQ / SUZ-KA50VA Брошюра
- Mitsubishi Electric SEZ-KD50VAQ / SUZ-KA50VA Руководство по установке
- Mitsubishi Electric SLZ-KA50VAL / SUZ-KA50VA Инструкция по эксплуатации
- Mitsubishi Electric SLZ-KA50VAL / SUZ-KA50VA Брошюра
- Mitsubishi Electric SLZ-KA50VAL / SUZ-KA50VA Руководство по установке
- Mitsubishi Electric MSZ-HJ35VA / MUZ-HJ35VA Инструкция по эксплуатации
- Mitsubishi Electric MSZ-HJ35VA / MUZ-HJ35VA Брошюра
- Mitsubishi Electric MSZ-HJ35VA / MUZ-HJ35VA Руководство по установке
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Инструкция по эксплуатации
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Брошюра
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Руководство по установке
- Mitsubishi Electric MJ-E16PX Инструкция по эксплуатации
- GE Monogram ZISS 480 NX SS Инструкция по эксплуатации
- GE Monogram ZISS 480 NX SS Брошюра
- GE Monogram ZISP 480 DX SS Инструкция по эксплуатации
- GE Monogram ZISP 480 DX SS Брошюра
- Mitsubishi Electric SEZ-KD25VAQ / SUZ-KA25VA Инструкция по эксплуатации
Скачать
Случайные обсуждения