Mitsubishi Electric PMFY-P40VBM-E [9/32] Operation

Mitsubishi Electric PMFY-P40VBM-E [9/32] Operation
9
GB
3. Operation
<Vane setting>
F1 F2 F3 F4
Fri
Swing Off Off
LouverVent.Vane
Cool
Room
AutoSet temp.
Mode Temp. Fan
Fri
<Vent. setting>
F1 F2 F3 F4
Fri
Low
Vent.
<Returning to the Main menu>
F1 F2 F3 F4
Main
Main display:
Cursor Page
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Note:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in “STAND BY” or “DEFROST” states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
Press the [F1] or [F2] button to go
through the vane setting options:
"Auto", "Step 1", "Step 2", "Step 3",
"Step 4", "Step 5" and "Swing".
Select the desired setting.
Auto
Auto
Swing
Step 1 Step 2
Step 4Step 3
Swing
Step 5
Select "Swing" to move the vanes
up and down automatically.
When set to "Step 1" through "Step
5", the vane will be fixed at the se-
lected angle.
under the vane setting icon
This icon will appear when the
vane is set to "Step 2" to "Step 5"
and the fan operates at "Mid 1"
to "Low" speed during cooling or
dry operation (depends on the
model).
The icon will go off in an hour, and
the vane setting will automatically
change.
Press the [F3] button to go through
the ventilation setting options in the
order of "Off", "Low", and "High".
* Settable only when LOSSNAY
unit is connected.
Off Low High
Off Low High
The fan on some models of in-
door units may be interlocked
with certain models of ventilation
units.
Press the [RETURN] button to go
back to the Main menu.
<Navigating through the pages>
Press [F3] to go to the previous
page.
Press [F4] to go to the next page.
F1 F2 F3 F4
Main
Main display:
Cursor Page
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
page
<Saving the settings>
F1 F2 F3 F4
OU silent mode
Mon Tue Wed Thu Fri Sat Sun
Start Stop Silent
-
Setting display:
day
Select the desired item, and press
the [SELECT] button.
The screen to set the selected item
will appear.
<Exiting the Main menu screen>
Press the [RETURN] button to exit
the Main menu and return to the
Main display.
F1 F2 F3 F4
Cool
Room
AutoSet temp.
Mode Temp. Fan
Fri
<Display of unsupported functions>
The message at left will appear if
the user selects a function not sup-
ported by the corresponding indoor
unit model.
F1 F2 F3 F4
Title
Not available
Unsupported function
Return:
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
F1 F2 F3 F4
Main
Main display:
Cursor Page
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Select "Vane·Louver·Vent. (Loss-
nay)" from the Main menu (refer to
page 8), and press the [SELECT]
button.
If no buttons are touched for
10 minutes, the screen will
automatically return to the Main
display. Any settings that have not
been saved will be lost.