MCZ Forma 115 [8/46] Connection to the external air intake
![MCZ Forma 115 [8/46] Connection to the external air intake](/views2/1336204/page8/bg8.png)
INSTALLATION AND USE MANUAL
Chapter 2
page 8
Theoretical notions for installation
Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
IMPORTANT!
The fireplace stove must be installed and
assembled by qualified personnel.
The fireplace stove must be connected to a flue
pipe or other vertical smoke stack that can
discharge smoke at the highest point of the
house.
The fireplace stove must be connected to a flue
pipe or an internal or external vertical duct
conforming to current standards UNI 7129 - 7131
9615.
Smoke is generated from burning wood and,
therefore, may dirty adjacent or nearby walls.
Before positioning the fireplace stove, you must
make a hole for the intake of external air.
2.3. CONNECTION TO THE EXTERNAL AIR INTAKE
The room where the stove is installed must have at least as much air as
requested by normal combustion of the equipment and by room
ventilation. This may take place through permanent apertures in the
room walls that lead directly outdoors or ventilated rooms according to
UNI 10683 REV.
For this purpose, drill a hole with minimum 360 cm² free section near
the fireplace stove (22 cm diameter or a 20x18cm rectangle), protected
by an indoor and outdoor grille.
The air intake must also:
directly communicate with the installation room
be protected by a grill, made of metallic anti-insect mesh or a
suitable protection as long as it does not reduce the minimum
section.
be installed so as to avoid obstruction
for ducts, up to 3.5 linear metres, increase the section by about
5% while increased by 15% for larger measurements.
Remember that the ventilation grills always have a cm
2
useful section on one side. When selecting the grill and hole
dimension, make sure the useful grill section is greater than
or equal to the section required by MCZ for product
operations.
Connecting the air outlet directly to the fireplace stove is not
mandatory but the above mentioned section must guarantee
about 50 m³/h of air. See standard UNI 10683 REV.
IMPORTANT!
Air flow may also be obtained from a room adjacent
to the installation room as long as this flow is free
through permanent apertures that directly
communicate with the outdoors; avoid air outlets
connecting with heating units, garages, kitchens or
bathrooms.
Содержание
- Use and installation manual 1
- Contents 2
- Contents 3
- How to read the manual 4
- Introduction 4
- Manual preservation 4
- Revisions to the publication 4
- These symbols signal specific messages in this booklet 4
- Operating warnings 5
- Safety warnings 5
- Warnings and warranty conditions 5
- Exclusions 6
- Important information for correct disposal of the product in accordance with ec directive 2002 96 ec 6
- Restrictions 6
- Warranty conditions 6
- Installation in accordance with uni 10683 7
- Operating area 7
- Precautions 7
- Connection to the external air intake 8
- Important 8
- Connection to the flue pipe 9
- Flue pipe 9
- Examples of flue pipes 10
- Important 10
- Technical specifications 17
- Installation and assembly 20
- Preparation and unpacking 20
- Selection of operating mode 20
- Forced convection vf 21
- Natural convection vn 21
- Positioning 21
- Release of counterweights 21
- Adjustment of height and balancing 22
- Air inlet for forced ventilation 23
- Air inlet for natural ventilation 23
- Combustion air inlet 23
- Ducts for kit comfort air 23
- External and internal air intake 23
- Connection to the flue pipe 24
- Installation of cladding and hood 24
- Hood ventilation nozzles 25
- Insulating a wooden beam 25
- Insulation of fireplace stove 25
- Comfort air kit natural ventilation and forced 26
- Components of forced ventilation kit with and without illumination 26
- Components of natural ventilation kit with and without illumination 26
- Ventilation 26
- A c d b 27
- Installation of the comfort air kit 29
- Variation for air outlet with container 30
- Variation for air outlet with illumination 30
- Maintenance of air outlet with illumination 31
- Composition of control unit 32
- Control unit 32
- Positioning of the control unit 32
- General information on the control unit 33
- On off 33
- Operation 33
- Light on if present 34
- Replacing the fuse of the control unit 34
- Safety function 34
- Door open switch 35
- Installation of temperature probe 35
- Connections 36
- Replacing the fan 37
- Attention 38
- Do not demand full heating 38
- Operating test 38
- Operation 38
- Performance straight away 38
- Pre lighting warnings 38
- Choice of fuel 39
- Phases for first test lighting 39
- First lighting 40
- Attention 41
- Loading the fuel 41
- Control of combustion 42
- Emergency situations 42
- Cleaning out the ashes 43
- Cleaning the glass 43
- Cleaning the refractory material walls alute 43
- Cleaning to be performed by the user 43
- Maintenance and cleaning 43
- Electric fan 44
- Lubrication and routine maintenance of the extensible guides 44
- Maintenance of kit vf if installed 44
- Cleaning flue pipe 45
- Cleaning to be dealt with by specialized technician 45
- Control unit comfort air 45
- Wiring 45
- E mail mcz mcz it 46
- Fax 39 0434 599598 46
- Internet www mcz it 46
- Mcz group s p a 46
- Telephone 39 0434 599599 pbx 46
- Via la croce n 8 46
- Vigonovo di fontanafredda pn italy 46
Похожие устройства
- MCZ Forma 115 Сертификат
- MCZ Forma 95 sx Инструкция по эксплуатации
- MCZ Forma 95 sx Сертификат
- MCZ Forma 95 Инструкция по эксплуатации
- MCZ Forma 95 Сертификат
- MCZ Forma 75 sx Инструкция по эксплуатации
- MCZ Forma 75 sx Сертификат
- MCZ Forma 75 dx Инструкция по эксплуатации
- MCZ Forma 75 dx Сертификат
- MCZ Forma T95 Инструкция по эксплуатации
- MCZ Forma T95 Сертификат
- MCZ Forma 75 Инструкция по эксплуатации
- MCZ Forma 75 Сертификат
- MCZ Forma T50 Инструкция по эксплуатации
- MCZ Forma T50 Сертификат
- CAS ER JR-15CB LT черные Инструкция по эксплуатации
- CAS ER JR-15CB черные Инструкция по эксплуатации
- MCZ HydroTherm 70 dx Инструкция по эксплуатации
- MCZ HydroTherm 70 dx Сертификат
- CAS ER JR-30CB LT черные Инструкция по эксплуатации