BEST Modular [10/40] English
![BEST Modular [10/40] English](/views2/1337015/page10/bga.png)
Содержание
- Betriebsanleitung 1
- Brugsanvisning 1
- Bruksanvisning 1
- Gebruiksaanwijzingen 1
- Instrucciones de uso 1
- Instructions for use 1
- Instructiuni de utilizare 1
- Instruções de uso 1
- Istruzioni per l uso 1
- Käyttöohjeet 1
- Mode d emploi 1
- Nàvod k pouziti 1
- Návod na pouzivanie 1
- Osny es xpó n 1
- Руководство по эксплуатации 1
- Mm 0150mm 2
- Comandi 8
- Filtrante o aspirante 8
- Italiano 8
- Scarico dell aria 8
- Anomalie di funzionamento 9
- Manutenzione 9
- Air vent 10
- Controls 10
- English 10
- Filtering or ducting version 10
- Maintenance 11
- Malfunctions 11
- Cpwcp c mc c og 12
- Deutsch 12
- Wartung 13
- Français 14
- Oq 0gpq 14
- Anomalies de fonctionnement 15
- Entretien 15
- Español 16
- Extracción de aire 16
- Filtrante o aspiradora 16
- Mandos 16
- Mandos 17
- Mantenimiento 17
- Anomalías de funcionamiento 18
- Comandos 19
- Filtrante ou aspirante 19
- Português 19
- Saída do ar 19
- Anomalias de funcionamento 20
- Manutenção 20
- Afvoer of recirculatie 21
- Bedieningselementen 21
- Luchtafvoer 21
- Nederlands 21
- Onderhoud 22
- Storingen 22
- Всасывающий тип 23
- Органы управления 23
- Отвод воздуха 23
- Русский 23
- Тип 23
- Только для вытяжек с электронным блоком управления 23
- Фильтрующая или всасывающая 23
- 0é об об об пб 24
- Pu2 pu3 24
- Замена ламп 24
- Замена угольного фильтра р 24
- Минутного таймера 24
- Органы управления 24
- Отображение скорости 24
- Примечание функция 5 минутный таймер может активироваться только в режиме обычных скоростей 1 ая 2 ая 3 я звуковой сигнал 24
- Сигнал тревоги фильтров 24
- Техническое обслуживание 24
- Функция 5 минутного таймера 24
- Чистка вытяжки 24
- Неисправности в работе 25
- Betjening 26
- Med filter eller udsugning 26
- Udluftning af luften 26
- Driftsfejl 27
- Vedligeholdelse 27
- Ilmanpoisto 28
- Ohjaimet 28
- Suodatin vai imuversio 28
- Huolto 29
- Ohjaimet 29
- Toimintaviat 29
- Filtrerande eller insugande 30
- Kommandon 30
- Luftutlopp 30
- Svenska 30
- Driftfel 31
- Kommandon 31
- Underhäll 31
- Ekkenqzh toy aepa 32
- Eààqviká 32
- Oiatpapizmatoz h anoppoohzhz 32
- Xeipizthpia 32
- Anqmaaiez aertoypriaz 33
- Xeipizthpia koupni 33
- Zynthphzh 33
- Comenzi 34
- Evacuarea aerului 34
- Filtrantà sau aspirantà 34
- Qwcp oq 0gpq 34
- Romàna 34
- Anomali de functionare 35
- Comenzi 35
- Întretinere 35
- Cestina 36
- Filtrujìcì nebo sacì 36
- Odtah vzduchu 36
- Príkazy 36
- Abnormàlnì funkce 37
- Ùdrzba 37
- Odvod vzduchu 38
- Ovládace 38
- S filtrovaním alebo s odvodom vzduchu 38
- Slovensky 38
- Chyby pri prevädzke 39
- Os qflb 39
- Ovlädace 39
- Üdrzba 39
Похожие устройства
- BEST Modular Каталог вытяжек BEST
- BEST Collier Инструкция по эксплуатации
- BEST Collier Каталог вытяжек BEST
- BEST Expo Standart черная Инструкция по эксплуатации
- BEST Expo Standart черная Каталог вытяжек BEST
- BEST Expo Lux белая Инструкция по эксплуатации
- BEST Expo Lux белая Каталог вытяжек BEST
- BEST K 508S Инструкция по эксплуатации
- BEST K 508S Каталог вытяжек BEST
- BEST K 508L Инструкция по эксплуатации
- BEST K 508L Каталог вытяжек BEST
- BEST Kasc 505L Инструкция по эксплуатации
- BEST Kasc 505L Каталог вытяжек BEST
- BEST Expo Lux черная Инструкция по эксплуатации
- BEST Expo Lux черная Каталог вытяжек BEST
- BEST Expo Standart белая Инструкция по эксплуатации
- BEST Expo Standart белая Каталог вытяжек BEST
- Hitachi EP-A9000 CH Инструкция по эксплуатации
- Hitachi EP-M70E WH Инструкция по эксплуатации
- BEST Theta 60 Инструкция по эксплуатации
English The appliance must be installed by a qualified person in compliance with the instructions provided A Wear gloves when carrying out installation and maintenance operations If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Only for hoods equipped with electronic control The 4th speed intensive is automatically lowered to 3rd speed after 5 minutes of operation to optimise energy consumption If the hood is left on lights and or motor after 10 hours in the absence of commands from the user it will automatically switch to OFF condition with all services switched off The Buzzer emits a beep each time that a command is set from the keyboard or remote control optional In the event of interruption of power during the hood if you restore the hood in the OFF state then the engine must be reactivate manually AIR VENT for ducting versions Prepare the hole and the air vent duct 150 mm diameter Use a duct of the minimum indispensible length Use a duct with as few elbows as possible maximum elbow angle 90 Avoid drastic changes in the duct cross section Use a duct with an as smooth as possible inside The duct must be made of certified material Do not connect the hood to smoke exhaust ducts for the products of combustion boilers fireplaces stoves etc For the air vents comply with the provisions laid down by the competent authorities In addition the air must not be evacuated through a hole in the wall unless specifically intended for this purpose Fit air intakes in the room to prevent the hood from creating a negative pressure in the room which must not exceed 0 04 mbar if the hood is used at the same time as non electrical equipment gas oil and charcoal fired stoves etc the exhaust gas may be sucked in by the heat source FILTERING OR DUCTING VERSION The hood may be in filtering or in ducting version Decide from the outset which type is to be installed For better efficiency we recommend installing the hood in the ducting version if possible version The hood purifies the air and recycles the clean air back into the room For this version the following are required 1 air baffle 1 reducer 2 charcoal filters The upper flue air evacuation slots must be positioned at the top CONTROLS I A Turns the LIGHTS off B Turns the LIGHTS on C Decreases speed down to minimum speed If pressed for 2 the motor is turned off D Activates the motor calling the last speed used and increases the speed until reaching maximum E FILTER ALARM TIMER RESET when pressing the key during display of the filter alarm motor off it resets the hour counter When pressing the key when the motor is running the TIMER is activated and the hood will automatically be switched off after 5 minutes L1 The 4 green LEDs indicate the running speed L2 When the LED is red motor off it indicates the FILTER ALARM When the LED is green flashing it indicates that the TIMER has been activated with the key E Filter alarm After 30h of operation the LED L2 turns RED It indicates that the grease filters need to be cleaned After 120h of operation the LED L2 turns RED and flashes It indicates that the grease filters need to be cleaned and the charcoal filters replaced After cleaning the grease filters and or replacing the charcoal filters restart the hour counter RESET by pressing the key E during display of the filter alarm CONTROLS Speed display PU5 ON OFF Motor 4lh speed PU4 ON OFF Motor 3rd speed PU3 ON OFF Motor 2nd speed PU2 ON OFF Motor 1a speed PU1 ON OFF Lights The hood purifies the air and evacuates it to the outside through an exhaust duct diameter 150 mm KEY LED