Airwell AQH 130 [16/28] Performance data in heating mode hfc 407c continued

Airwell AQH 130 [16/28] Performance data in heating mode hfc 407c continued
Page 16
Performance data in heating mode - HFC 407C (continued)
LHWT
(°C) Pc Pabs Pc Pabs Pc Pabs Pc Pabs Pc Pabs Pc Pabs Pc Pabs
30
68.2 24.5 72.7 24.5 79.9 24.5 92.6 24.6 98.4 24.6 105.2 25.4 117.8 26.7
35
68.2 27.1 72.5 27.1 79.4 27.1 91.8 27.1 97.3 27.2 103.8 27.9 115.8 29.3
40
68.5 30.2 72.6 30.1 79.2 29.9 91.0 29.9 96.3 29.9 102.5 30.8 113.9 32.3
45
69.1 33.7 72.8 33.5 79.1 33.2 90.4 33.2
95.4 33.2
101.2 34.0 112.0 35.7
50
69.7 36.4 73.2 36.2 79.1 35.9 89.9 35.5 94.9 35.4 100.6 36.1 111.2 37.1
30
75.3 27.9 79.7 28.0 87.5 28.1 101.4 28.3 107.6 28.5 115.1 29.4 129.0 31.1
35
75.8 31.2 80.3 31.1 87.7 31.2 101.2 31.4 107.3 31.6 114.5 32.6 127.9 34.5
40
76.6 34.7 80.8 34.7 88.0 34.6 101.1 34.8 107.0 35.0 113.9 36.1 126.7 38.1
45
77.4 38.6 81.4 38.5 88.3 38.5 100.9 38.6
106.6 38.7
113.0 39.8 125.3 42.0
50
77.6 39.8 81.6 39.8 88.4 39.7 100.8 40.4 106.3 41.1 112.3 43.3 123.7 46.3
30
87.5 29.9 93.6 30.0 103.6 30.1 121.2 30.4 129.0 30.5 138.5 31.5 156.0 33.3
35
87.7 33.1 93.6 33.2 103.3 33.2 120.4 33.5 128.0 33.6 137.0 34.7 153.9 36.7
40
87.7 36.6 93.4 36.6 102.9 36.8 119.5 37.0 126.8 37.2 135.5 38.3 151.8 40.4
45
87.5 40.2 93.1 40.4 102.3 40.5 118.4 40.8
125.6 41.0
133.9 42.2 149.6 44.5
50
87.2 43.8 92.7 43.9 101.7 44.1 117.6 44.0 124.6 44.0 132.9 44.9 148.5 46.7
30
95.1 32.3 101.5 32.4 111.7 32.6 130.0 32.9 138.3 33.0 148.1 34.0 166.5 36.1
35
95.4 35.8 101.7 35.8 111.6 36.1 129.6 36.4 137.6 36.6 147.1 37.8 164.9 39.9
40
95.6 39.6 101.7 39.7 111.5 40.0 129.0 40.3 136.8 40.5 145.9 41.8 163.1 44.2
45
95.7 43.8 101.7 43.9 111.2 44.2 128.2 44.5
135.8 44.7
144.6 46.1 161.0 48.7
50
95.7 47.7 101.6 47.8 110.9 47.9 127.5 47.9 134.9 48.0 143.6 49.1 159.8 51.1
30
100.0 34.0 106.5 34.1 117.2 34.3 136.7 34.5 145.3 34.7 155.7 35.7 175.3 37.7
35
100.0 37.5 106.4 37.5 116.9 37.8 135.8 38.1 144.3 38.2 154.3 39.4 173.2 41.5
40
100.0 41.2 106.2 41.4 116.5 41.6 134.8 42.0 143.0 42.1 152.7 43.4 170.8 45.8
45
99.8 45.4 105.9 45.5 115.9 45.8 133.7 46.1
141.0 46.3
150.8 47.7 168.0 50.2
50
99.5 49.8 105.5 49.9 115.2 50.0 132.5 50.0 140.2 50.0 149.2 51.2 166.1 53.2
130
90
100
110
120
AQH
sizes
Outdoor air temperature (°C)
-5 -3 0 5 7 10 15
All the heating capacity and power consumption values are expressed in kW.
The values indicated in bold are based on : hot water of 40/45 °C and an outdoor air temperature of +7 °C.
The power consumption values stated in the table include compressors and fans in operation.
LHWT: Leaving Hot Water Temperature
Pc : Heating capacity
Pabs : Power consumption