Part 9 Gas convertion Your cooker can operate both Natural Gas and LPG You can convert by changing the gas source and the top burner oven and grill injectors The replacement procedure of the injectors are explained below Call authorized Service for gas convertion Replacement of the top burner injector Take off the burner head and burner cap before starting this procedure Then 1 Remove the injector inside the top burner with a suitable bit Later install the new injector by covering the injector threads with leakage preventing Flame failure material device spark plug Injector Burner Reduced Tap Flow In models with Removal of the control panel Removal of the control panel 1 Open the front door 2 Unscrew the two screws of the control panel and take the control panel bottom sheet 3 Release the control panel from the two notches at the top slightly pull it to the bottom front and keep it free with its cables connected Ignite the burner that should be adjusted turn the knob to the reduced position pull and take the knob off 4 With a screwdriver make the tap reduced flow adjustment from the injector that is on the gas tap only the head is visible with the bolt shape It is sufficient to tight to screw completely in butane propane gas For the natural gas you should turn the screw counter clockwise once The normal length of a straight flame in the reduced position 31 should be 6 7mm If the flame is higher than the desired position turn the screw clockwise If its smaller to the opposite For the last control of the burning of the cooker bring the cooker high flame and reduced positions and check whether the flame is on or off