Biral HXD 652 [24/60] English

Biral HX 502-1 [24/60] English
english
24
LX LXD
Single pumps Twin pumps
LX 325, LX 401, LX 402 LXD 401, LXD 402 0,1 bar
LX 326, LX 403 LXD 403 0,1 bar
LX 502 0,1 bar
LX 503, LX 504 LXD 503, LXD 504 0,2 bar
LX 652 0,5 bar
LX 653, LX 654, LX 655 LXD 653, LXD 654, LXD 655 0,6 bar
LX 802, LX 803 LXD 802, LXD 803 0,6 bar
HX HXD
Single pumps Twin pumps
HX 402, HX 402-1 HXD 402-1 0,4 bar
HX 501, HX 502,
HX 501-1, HX 502-1 HXD 501-1, HXD 502-1 0,5 bar
HX 652 HXD 652 1,0 bar
HX 802 HXD 802 1,6 bar
The values apply up to 500 m (1640 ft) above sea level.
Additional pressure for greater heights:
0.01 bar per 100 m (328 ft) additional altitude.
Additional pressure for: 90 °C 0,35 bar
110 °C 1,10 bar
140 °C 3,30 bar
4.7 Minimum pressure
At 75° the minimum pressure
at the pump intake,
when the pump is running,
is to ensure lubrication
of the sleeve bearings:
4.6 Flange connection
The pump flanges are bored
with fixing holes PN6 / PN10 /
PN16.
The plain washers «B»
provided are to be installed
on the pump side to ensure
that the flanges are securely
fastened.
Admissible screw torque:
for M 12 40 Nm
for M 16 95 Nm
The installation of combination flange
with combination flange is not admissible.
PN 6 PN 10 / PN 16 PN 6 PN 10 / PN 16
DN 40
DN 50 M 12 M 16 Ø 14 Ø 18
DN 65
Use the appropriate screws
for the given nominal pressure PN.
AB
Safety elements (such as spring lock washers)
are not admissible.
Warning

Содержание