Fluke 709 [20/20] 709h 710
Содержание
- 709h 710 1
- 709h 710 calibration manual 1
- Warranty 2
- Table of contents 3
- Contact fluke 5
- Introduction 5
- To prevent possible electrical shock fire or personal injury read all safety information before you use the product 5
- Xw warning 5
- Safety information 6
- Specifications 6
- Battery replacement 8
- Clean the product 8
- Maintenance 8
- Xw warning 8
- Precision loop calibrator 9
- 709h 710 10
- Performance verification tests 10
- Required test equipment 10
- Table 1 is a list of the required equipment for the performance verification tests and calibration adjustment 10
- The performance tests verify the complete operation of the product and measure the accuracy of each function against product specifications if the product fails a part of the test calibration adjustment or repair is necessary see calibration adjustment procedure 10
- The performance verification tests check the accuracy of each product function against its specifications if the product fails any of these tests calibration adjustment or repair is necessary 10
- To prevent possible electrical shock fire or personal injury do not perform the performance test or verification test procedures unless the product is fully assembled 10
- Xw warning 10
- Dc current source mode 11
- 709h 710 12
- A connect a test lead from the red aux terminal of the dc calibrator calibrator to the dmm i input 12
- B connect a test lead from the black aux terminal of the calibrator to the com terminal on the product 12
- C connect a test lead from the dmm lo input to the product terminal see figure 3 12
- Connect the product 12
- Dc current measurement mode 12
- Disconnect all connections to the product 12
- Make sure that the product shows source in the upper left corner 12
- Push the rotary knob 12
- See table 2 to verify the readings on the dmm for the subsequent tests no adjustment is necessary for test 1 12
- Set the dmm to measure dc current 12
- Test 2 push twice to select 12 00 ma verify the readings 12
- Test 3 push twice to select 20 00 ma push and rotate the knob until 24 00 ma is shown verify the readings 12
- The product shows measure 12
- To verify the performance of the dc current measurement function 12
- Turn the rotary knob to select ma measure 12
- Dc voltage measurement mode 14
- Hart transmitter 709h 710 only 15
- Calibration adjustment procedure 16
- Ma measure mode 16
- Ma source 17
- Voltage measure 18
- Precision loop calibrator 19
- User replaceable parts 19
- User replaceable parts are listed in table 3 and shown in figure 6 for more information about these items and their prices contact a fluke representative see the contact fluke section 19
- 709h 710 20
- Calibration manual 20
- Figure 6 user replaceable parts 20
Похожие устройства
- Fluke 773 Приложение к Инструкции
- Fluke 773 Положение об энергозависимости памяти
- Fluke 773 Clamp Meter data sheet
- Fluke 773 Руководство по калибровке
- Fluke 772 Положение об энергозависимости памяти
- Fluke 772 Приложение к Инструкции
- Fluke 772 Clamp Meter data sheet
- Fluke 772 Руководство по калибровке
- Fluke 771 Приложение к Инструкции
- Fluke 771 Приложение к руководству по калибровке
- Fluke 771 Руководство по калибровке
- Fluke 715 Положение об энергозависимости памяти
- Fluke 715 Loop Calibrators Data Sheet
- Fluke 715 Приложение к Инструкции
- Fluke 718 Приложение к Руководству по эксплуатации
- Fluke 712 Приложение к Инструкции
- Fluke 714 Приложение к Инструкции
- Fluke 717 Приложение к руководству по калибровке
- Fluke 717 Приложение к Инструкции
- Fluke 717 Руководство по калибровке
Скачать
Случайные обсуждения