D-Link DGS-6608 — установка и настройка управляемого коммутатора Ethernet Layer 3 [87/111]
Превью страниц
Страница 87 /
111
![D-Link DGS-6608 [87/111] Password protection](/views2/1459372/page87/bg57.png)
DGS-6600 Layer 3 Chassis Ethernet Managed Switch Hardware Installation Guide
75
The Switch CM is assigned a unique MAC address by the factory. This MAC address cannot be changed, and
can be found by entering the command show system into the command line interface. The MAC address of the
CM management ethernet port can be seen below in the information section for Slot 1
The Switch's MAC address also appears in the Device Information and System Information windows of the Web-
based management interface.
Password Protection
The DGS-6604 does not have a default user name and password. One of the first tasks when settings up the
Switch is to create user accounts. Logging in using a predefined administrator-level user name will give the user
privileged access (Privileged EXEC) to the Switch's management software.
After the initial login define new passwords for both default user names, to prevent unauthorized access to the
Switch, and record the passwords for future reference.
To create an administrator-level account for the Switch, do the following:
Creating User Accounts
The Switch supports user accounts with different access levels. The following access levels can be assigned to
user accounts, Level 1, Level 2, Level 12, & Level 15. If another level is specified, an error message will be
displayed on the console.
When a user logs in with a Level 1 or Level 2 account, the user will access the Switch in user EXEC mode. In
order to access higher privilege levels, a user needs to use the enable command. However, if a user logs onto
the Switch using a Level 1 user account, they will not be allowed to enter privileged EXEC mode.
When a user logs in with a user account that has a privilege level of 12 or 15, the user will directly enter privileged
EXEC mode.
DGS-6600:15(mgmt-if)#show system
Device Type :Chassis-based High-Speed Switch
First MAC Address :00:01:02:03:04:00
Number of MAC Address(es) :4096
Slot: 1
Hardware Version :0A1G
Bootloader Version :2.10.001
Firmware Version :2.10.001
S/N :123456789-123456789-123456789-0123456789
Model Name :DGS-6600-CM
First MAC Address :06:60:0c:10:00:35
Number of MAC Address(es) :1
Slot: 4
Hardware Version :0A1G
Bootloader Version :2.10.001
Firmware Version :2.10.001
S/N :123456789-123456789-123456789-0123456789
Model Name :DGS-8000-48P
First MAC Address :00:01:02:03:04:00
Number of MAC Address(es) :48
Содержание
204- Fcc warning
- Ce mark warning
- Chapter 2 installation 43
- Chapter 1 introduction 1
- Chapter 5 web based switch management 78
- Chapter 4 introduction to switch management 69
- Chapter 3 connecting the switch 65
- Chapter 6 maintenance 83
- Chapter 7 troubleshooting 86
- Typographical conventions
- Intended readers
- Safety suggestions
- Safety recommendations for removing and replacing batteries
- Safety recommendations for handling the switch
- Notes notices and cautions
- Safety precautions for installing and removing the switch
- Electrical safety
- Preventing static discharge damage
- Grounding requirements
- Laser safety
- Dgs 6604 product specifications
- Dgs 6600 series switch description
- Chapter 1 introduction
- Product features
- Dgs 6604 product appearance
- Module plug in frame
- Dgs 6604 hardware composition
- Chassis
- Product features
- Dgs 6608 product specifications
- Dgs 6604 ventilation heat dissipation system
- Dgs 6608 product appearance
- Module plug in frame
- Dgs 6608 hardware composition
- Chassis
- Dgs 6608 ventilation heat dissipation system
- Dgs 6600 cpu i o modules ac dc power
- Interface
- Dgs 6600 cm module
- Uart console interface
- Out of band management port
- Technical specifications
- Uart console interface
- Out of band management port
- Interface
- Dgs 6600 cm ii management module
- Technical specifications
- Interface
- Dgs 6600 24sc2xs module
- Technical specifications
- Interface
- Dgs 6600 24sc2xs c module
- Technical specifications
- Interface
- Dgs 6600 16xs d
- Technical specifications
- Interface
- Dgs 6600 48p module
- Technical specifications
- Interface
- Dgs 6600 48s module
- Technical specifications
- Interface
- Dgs 6600 48s c module
- Technical specifications
- Interface
- Dgs 6600 48t module
- Technical specifications
- Interface
- Dgs 6600 48ts module
- Technical specifications
- Interface
- Dgs 6600 8xg module
- Technical specifications
- Dgs 6600 pwr module
- Technical specifications
- Maximum output power of multiple supply modules for dgs 6604 3 1
- Maximum output power of multiple supply modules for dgs 6608 4 4
- Dgs 6600 pwrdc module
- Technical specifications
- Maximum output power of multiple supply modules for dgs 6604 3 1
- Maximum output power of multiple supply modules for dgs 6608 7 1
- Rack mounting requirements
- Installation site requirements
- Chapter 2 installation
- Ventilation requirements
- Power requirements
- System grounding requirements
- Safety grounding
- Lightning grounding
- Precautions for fiber connections
- Installation tool requirements
- Emi considerations
- Inventory
- Inspection requirements when unpacking the switch
- Verifying the installation
- Installation flowchart
- Installing the cabinet
- Cabinet installation precautions
- Simple installation steps
- Mounting the dgs 6600 series switch into the cabinet
- Cabinet mounting precautions
- Fan tray installation
- Figure 2
- Power supply installation
- Air filter installation
- System ground connection
- Simple grounding steps
- Grounding precautions
- Ground connection
- Connecting the power supply to the power module
- Simple power connection steps
- Power supply connection precautions
- Simple management module cable connection steps
- Removing line cards from the dgs 6600 series switch
- Connecting the management module cable
- Installing line cards in the dgs 6600 series switch
- Cable management precautions
- Cable management
- Simple external interface cable connection steps
- Simple cable management steps
- Connecting the external interface cables
- Connecting external interface cable precautions
- Installation checks
- Checking the power supply
- Checking the cables
- Checking the cabinet
- Switch to end node
- Chapter 3 connecting the switch
- Chassis to switch
- Connecting to network backbone or server
- Connecting the external interface cables
- Connecting external interface cable precautions
- Cable management precautions
- Cable management
- Simple external interface cable connection steps
- Simple cable management steps
- Connecting the management module cable
- Web based user interface
- Snmp based management
- Remote command line interface using telnet
- Management options
- Chapter 4 introduction to switch management
- To connect a terminal to the console port
- Connecting the console port
- Command line interface through the serial ports
- First time connecting to the switch
- Connecting to the ethernet management port
- Password protection
- Creating user accounts
- Saving configuration changes
- Snmp settings
- Management information base mib
- Introduction
- Chapter 5 web based switch management
- Enabling and configuring the web user interface
- Web based user interface web ui
- Logging onto the web manager
- Areas of the user interface
- Configuring the management interface using the web ui
- Chapter 6 maintenance
- Maintaining the ventilation system
- Maintaining the dgs 6600 series switch hardware
- Maintaining the dgs 6600 modules
- Dgs 6600 series switch monitoring function
- Remote maintenance
- Maintaining the power supply
- General flow chart for troubleshooting installation faults
- Chapter 7 troubleshooting
- Troubleshooting
- Fault 3 the line card leds do not light as expected when the switch is powered on
- Fault 2 the ac power module is not working
- Fault 1 the system login password has been forgotten
- Description
- Common troubleshooting procedures
- Troubleshooting
- Fault 6 the fan tray does not work the fan tray s led behavior is unusual
- Fault 5 the led of the control management module is abnormal
- Fault 4 the leds on a line card start to behave strangely after the line card has been working for a while
- Description
- Fault 8 illegible characters appear in the serial port console
- Fault 7 there is no output from the console when connected to the serial port
- Description
- Troubleshooting
- Technical specifications 6604
- General
- Appendix a technical specifications
- Environment
- Weight
- Technical specifications 6608
- Power supply fan
- General
- Dimensions
- Environment
- Weight
- Power supply fan
- Dimensions
- Sfp module models and technical specifications
- Connection modules
- Xfp module models and technical specifications
- Base t 100base tx 10base t port
- Appendix b connectors and connection media
- Sfp module models and technical specifications
- Optical fiber connection
Похожие устройства
-
D-Link DGS-3130-54TSРуководство по настройке -
D-Link DXS-3600-16SСжатое руководство пользователя -
D-Link DGS-1100-08P/AБыстрый старт -
D-Link DGS-1100-08P/BБыстрый старт -
D-Link DXS-3400-24TCКраткая инструкция -
D-Link DXS-1100-10TSСжатое руководство пользователя -
D-Link DGS-3620-28SCБыстрый старт -
D-Link DGS-3630-28TCЭксплуатационная инструкция -
D-Link dgs-1510-28Руководство по быстрому запуску -
D-Link dgs-1510-52Краткий обзор функций -
D-Link DGS-1100-08PDРуководство по работе с устройством -
D-Link DGS-6608Руководство пользователя _CLI_
Подробное руководство по установке и настройке управляемого коммутатора Ethernet Layer 3. Узнайте, как создать учетные записи пользователей и управлять доступом.