Aurora A-1790D — настройка параметров для системы управления швейной машины [86/151]

Aurora A-1790D Панель управления _eng_ онлайн [86/151] 409087
Mode Setting Computerized Control System for Square Buttonhole Machine
76
Check the changed parameters
A When parameter is changed, the system will
display “Modified” key at parameter setting
interface.
B In the parameter setting interface, press
Modified to check the changed
parameters.
At first, the system will ask user to input the
password. For the operation at password input
interface, please refer to the “A” at . After
inputting the right password, user can enter the
interface for inquiring changed parameters.
C Under the interface of changed parameter
inquiry, user can find the list containing all the
changed parameters with their current value
and default value.
In that interface
z PressAll Rest will restore all the
changed parameters to their default
values
z Click Parameter Name, like Presser
Type and then pressSelect Rest.to
restore this parameter to the default
value. User can select many parameters
at here.
z Press Parameter Number, likeU14 to
enter the parameter setting interface,
where user can reset the parameter
value.
z When the pages are more than one, user
can use arrow key to turn the page.
z Press
to quit the interface.
List of Level 1 Parameters
No. Parameter Range Unit Default value
U01
Presser up to maximum position
Height of maximum position of pedal operation is set.
0~17.0 0.1mm 6.mm
U02
Presser up to intermediate position
Height of intermediate position of pedal operation is
set.
0~14.0 0.1mm 6.0mm
U03
Presser lifter cloth setting position
Height of cloth at of pedal operation is set.
0~14.0 0.1mm 0
U04
Down position of 2-pedal (%)
Set the operation of the 2-pedal
5~95 1% 80%