17
8.5 Stopping the generator
Stop the generator with the green button “START/STOP” (fig. 3 3, page 4).
The inverter shuts down immediately. The engine runs for 30 seconds to cool
down, then the engine stops too.
A
8.6 Display messages
NOTICE!
Always stop the generator with the green button “START/STOP” to
avoid engine damages. The turn off procedure with the red button has
to be used only for emergency.
Display message
Description
Generator behaviour Measures
LOW BATTERY
The battery voltage has fallen
below the minimum value for
starting up (9 V).
The generator does not start. Charge the battery.
Check OIL Level
The generator continues to run. Fill up with oil (see chapter
“Checking the oil level” on
page 20).
OIL CHANGE
The number of prescribed oper-
ating hours has been reached for
changing the engine oil.
The generator continues to run. Change the oil (see chapter
“Changing the oil” on page 23),
then confirm the message by
pressing and holding down the
button START/STOP. Restart the
generator by again pressing and
holding down the button
START/STOP.
Only TEC60:
NO FUEL
The petrol in the tank is in
reserve.
The generator continues to run. Refuel.
OIL ALERT
Insufficient engine oil.
The generator stops. Fill up with oil (see chapter
“Checking the oil level” on
page 20).
TEC60-TEC60LPG-O-16s.book Seite 17 Donnerstag, 14. Juli 2016 7:05 19