Dometic TEC 60 [23/364] Finishing maintenance work

Dometic TEC 60 [23/364] Finishing maintenance work
EN
TEC60, TEC60LPG Servicing the generator
23
10.3 Finishing maintenance work
Connect the generator to the positive terminal of the supply battery.
Switch the generator to standby with the main switch (fig. 4 1, page 4).
Close the generator flap.
10.4 Changing the oil
!
A
You may use the following oil:
SAE 5W-30 grade oil (can be used at any temperature).
Oil with single grade oil viscosity.
Select the appropriate viscosity according to the average temperature on-site.
Change the oil as follows:
Allow the generator to run until warm so that the oil can drain off faster and
completely.
Place a suitable receptacle under the drain plug (fig. 6 1, page 5).
Remove the dipstick.
Take out the drain plug (fig. 6 1, page 5).
The oil drains off.
Pour fresh oil into the filler neck.
The amount of oil is: 1.1 l.
CAUTION!
Hot oil can cause burns.
NOTICE!
Only dispose of used oil at a specialist recycling station and observe the
local laws for environmental protection.