Dometic TEC 60 [20/364] Checking the oil level

Dometic TEC 60 [20/364] Checking the oil level
EN
Operating the generator TEC60, TEC60LPG
20
8.7 Checking the oil level
!
I
Always check the oil level before use. To do this, proceed as follows:
Open the generator flap.
Switch the generator to no function with the main switch (fig. 4 1, page 4).
Disconnect the positive terminal of the supply battery.
Take the dipstick (fig. 4 2, page 4) out of the filler neck (fig. 4 3, page 4).
Clean the dipstick (fig. 4 2, page 4) with a cloth.
Put the dipstick (fig. 4 2, page 4) back into the filler neck (fig. 4 3, page 4).
Take the dipstick (fig. 4 2, page 4) out of the filler neck.
Check that the oil level is between the notch (maximum filling level) and the tip of
the dipstick.
If not, top up with more oil.
Put the dipstick (fig. 4 2, page 4) back into the filler neck (fig. 4 3, page 4).
Check that the oil level is not above the maximum level.
Connect the generator to the positive terminal of the supply battery.
Switch the generator to standby with the main switch (fig. 4 1, page 4).
Close the generator flap.
CAUTION!
Hot oil can cause burns.
Only check the oil level when the generator is switched off.
NOTE
The generator must be level.
TEC60-TEC60LPG-O-16s.book Seite 20 Donnerstag, 14. Juli 2016 7:05 19