CMI C-TP 400 — руководство по устранению неисправностей и утилизации насосов [22/68]

Превью страниц Страница 22 / 68
CMI C-TP 400 [22/68] Technical data
22
If you can’t fix the fault yourself, contact your nearest
vendor. Please be aware that any improper repairs
will also invalidate the warranty and additional costs
may be incurred.
Disposal
Disposal of the appliance
Appliances which are labelled with the adja-
cent symbol must not be disposed of in
household waste. You must dispose of such
old electrical and electronic equipment sep-
arately.
Please check with your local authority about the
possibilities for correct disposal.
Through separate disposal you send old equipment
for recycling or for other forms of re-use. You will
thus help to avoid in somecases that damaging
material gets into the environment.
Disposal of the packaging
The packaging consists of cardboard and
correspondingly marked plastics that can
be recycled.
Make these materials available for
recycling.
Technical data
Residual current circuit breaker
(RCCB) triggered?
Activate RCCB. Contact qualified electrician if
RCCB triggers again.
Motor defective? Contact your local vendor.
Pump runs but does not
pump.
Suction openings blocked? Rectify blockage.
Pump draws in air? Keep the pump at an angle while submerging.
Switch the pump on and off several times in or-
der to expel air.
Pump blocked by foreign bodies? Clean the pump (Cleaning the suction ar-
ea– p.21).
Delivery rate too low. Delivery height too great? Comply with maximum delivery height
(Technical data– p.22).
Pressure line diameter too small? Use pressure line with larger diameter.
Pressure line blocked? Rectify blockage.
Suction openings blocked? Clean suction opening.
Pressure line kinked? Straighten pressure line.
Pressure line leaks? Seal pressure line, tighten threaded connec-
tions.
Pump runs very loudly. Pump draws in air? Ensure there is sufficient liquid present.
Adjust float switch correctly (Operation–
p.21).
Keep the pump at an angle while submerging.
Pump does not switch
off.
Float switch does not reach the bot-
tom position?
Pull out the plug.
Ensure that the float switch can move suffi-
ciently.
Float switch defective? Contact your local vendor.
Fault/malfunction Cause Remedy
Item number 420 602 420 603
Model C-TP250 C-TP400
Rated voltage 230V~, 50Hz 230V~, 50Hz
Rated power 250W 400W
Protection type IPX8 IPX8
Max. supply height 6m 5m
Max. flow rate 6000l/h 8000l/h
Max. submersion depth 7m 7m
Max. temperature of liquid 35°C 35°C
Pressure pipe diameter
Pipe connection
Hose connection
G38mm (1½")
25–32mm (1–1¼")
G38mm (1½")
25–32mm (1–1¼")
GB
Tauchpumpe_420602_420603.book Seite 22 Mittwoch, 4. November 2015 11:16 11

Содержание

296

Узнайте, как правильно устранить неисправности насосов и утилизировать старое оборудование. Следуйте рекомендациям для безопасной эксплуатации и экологии.