Emotron FLD48-023-2Y [17/20] Common mode filter
![Emotron FLD48-008-54 [17/20] Common mode filter](/views2/1574009/page17/bg11.png)
17
www.emotron.com
Sine wave lter
Rated voltage= 400 V ±25%, 50/60 Hz (690 V on request).
Max. 40°C ambient temperature. IP20= with enclosure and screw
terminals. IP00=no enclosure and busbar connections.
Voltage drop approximately 25 V at rated current, 50 Hz.
Overload: 110% for 5 min, 150% for 2 min or 200% for 30 s.
For further information see filter selection guide, page19
Common mode lter
Common mode filters are mainly used to reduce common mode currents in motors (typically
used with motors >size 280). Common mode filters can prevent damage of motor bearings.
All three motor phases (without shield) are to be routed through common mode filter rings.
These filters can also be used to reduce EMC emissions in supply cables.
Part no. 052213
Filter type
3AFS400-
Protection
class
Power
[kW]
Nom. current
(I
N
) A/Phase
Power loss
[W]
Weight
[kg]
Dimensions
HxWxD [mm]
002.5 IP20 0.75 2.5 75 5 190x165x160
004 IP20 1.5 4 90 5 190x165x160
007 IP20 2.2 7 125 7 250x162x162
010 IP20 4 10 165 9 250x162x162
013 IP20 5.5 13 190 12 250x162x162
016 IP20 7.5 16 220 13 300x210x180
025 IP20 11 25 250 18 300x250x210
035 IP20 15 35 275 25 300x270x235
010 IP00 4 10 165 9 195x200x115
013 IP00 5.5 13 190 12 225x200x115
016 IP00 7.5 16 220 13 225x240x135
025 IP00 11 25 250 18 270x250x160
035 IP00 15 35 275 25 270x250x160
050 IP00 22 50 320 45 280x300x250
063 IP00 30 63 550 49 270x300x370
080 IP00 37 80 380 65 324x360x320
100 IP00 45 100 530 65 324x360x320
125 IP00 55 125 650 85 335x390x320
150 IP00 75 150 580 119 440x480x340
180 IP00 90 180 760 131 440x480x340
250 IP00 132 250 600 135 420x420x390
300 IP00 160 300 1000 140 420x420x390
Liquid cooling
Drive modules in frame sizes E, F and F69 are available in a liquid cooled version. These units
are designed for connection to a liquid cooling system, normally a heat exchanger of liquid-
liquid or liquid-air type. Heat exchanger is not part of the liquid cooling option. The drive units
are equipped with rubber hoses with leak-proof quick couplings.
Содержание
- Technical catalogue emotron flowdrive 1
- Contents 2
- Dedicated waste water drive 2
- Emotorn flowdrive page 3 specifications page 7 2
- General information overview for emotron flowdrive 2
- Speed control offers great energy and maintenance savings emotron ac drives ensure high efficiency and reliability whether your need is to adapt a pump s operation to variations in flow our ac drives emotron flowdrive are available in sizes 0 5 3000 kw 230 690v and with protection class ip20 ip21 and ip54 2
- Standard options page 13 2
- Emotron flowdrive dedicated waste water drive 3
- Emotron flowdrive ip54 version 4
- Typical motor power at mains voltage 230v 400v and 460v 4
- Emotron flowdrive ip54 version 5
- Typical motor power at mains voltage 525v 575v and 690v 5
- Emotron flowdrive ip20 version 6
- Typical motor power at mains voltage 230v 400v and 460v 6
- Coated boards 3c 7
- Environmental conditions 7
- General specifications 7
- General specifications for emotron flowdrive 7
- Dimensions weights and cooling air flow 8
- Operation at higher temperatures 8
- Possible derating 8
- Standards 8
- Ip2y and ip20 21 version of emotron flowdrive 9
- Mechanical specifications for model flowdrive ip2y and ip20 21 version 9
- Mechanical specifications for models fld48 fld52 fld69 ip54 version 10
- Basic i o data 11
- User interface data 12
- All boards are coated support for 2 option boards and one communication option 13
- All boards are uncoated available as coated on request support for 3 option boards and one communication option 13
- Frame sizes a3 c3 frame sizes c2 f2 and b f 13
- Ip2y ip20 21 and ip54 13
- Isolated rs232 rs485 serial communication board for modbus rtu communication protocol baud rates 2400 38400 bits s supported 13
- Part no remark part no remark 13
- Ptc isolated input conforming din 44081 44082 max 6 ptc thermistors can be connected in series to ptc input also including 3 pt100 inputs 2 3 4 wire conforming en 60751 13
- Ptc isolated input conforming din 44081 44082 max 6 ptc thermistors can be connected in series to ptc input rtc real time clock function for flowdrive makes it possible to start functions at desired date time or weekday 13
- Ptc pt100 board 13
- Ptc rtc board 13
- Rs232 rs485 isolated 13
- Rtc board 13
- Rtc real time clock function for flowdrive makes it possible to start functions at desired date time or weekday 13
- Standard option 13
- Standard options 13
- Standard options for emotron flowdrive 13
- Control panel kit incl blank panel 14
- Control panel kit incl control panel 14
- Ethernet etherca 14
- Ethernet ethernet ip 2 port 14
- Ethernet modbus tcp 14
- Ethernet modbus tcp m12 14
- Ethernet profinet io 1 port 14
- Ethernet profinet io 2 port 14
- Fieldbus and ethernet boards 14
- Fieldbus devicenet 14
- Fieldbus profibus 14
- Safe stop 14
- Standard options for emotron flowdrive 14
- Standby power supply 14
- Blank control panel 15
- Dc dc connection 15
- Emc filter class c2 15
- Emosoftcom 15
- Factory mounted options for emotron flowdrive 15
- Glands for ip54 frame sizes b c and d 15
- Safe stop 15
- Standard options for emotron flowdrive 15
- Standby power supply 15
- Extended emc filter 90 300a 16
- Extended options for emotron flowdrive 16
- Output choke du dt 16
- Overshoot clamp 16
- Common mode filter 17
- Liquid cooling 17
- Sine wave filter 17
- Cad drawings available on the web 18
- Filter selection guide 18
- Emotron services 20
- Service and support secure the value of your investment 20
- Technical centres 20
Похожие устройства
- Emotron FLD48-023-2Y Руководство по эксплуатации
- Emotron FLD48-032-2Y Каталог
- Emotron FLD48-032-2Y Руководство по эксплуатации
- Emotron FLD48-038-2Y Каталог
- Emotron FLD48-038-2Y Руководство по эксплуатации
- Emotron FLD48-025-20 Каталог
- Emotron FLD48-025-20 Руководство по эксплуатации
- Emotron FLD48-030-20 Каталог
- Emotron FLD48-030-20 Руководство по эксплуатации
- Emotron FLD48-036-20 Каталог
- Emotron FLD48-036-20 Руководство по эксплуатации
- Emotron FLD48-045-20 Каталог
- Emotron FLD48-045-20 Руководство по эксплуатации
- Emotron FLD48-058-20 Каталог
- Emotron FLD48-058-20 Руководство по эксплуатации
- Emotron FLD48-072-20 Каталог
- Emotron FLD48-072-20 Руководство по эксплуатации
- Emotron FLD48-088-20 Каталог
- Emotron FLD48-088-20 Руководство по эксплуатации
- Emotron FLD48-105-20 Каталог