Weldy MINIWELDER GEO2 (154.880) [13/96] Error messages

Weldy MINIWELDER GEO2 (154.880) [13/96] Error messages
13
The power voltage must correspond with the value given on the nameplate. Extension cords must have a
conductor cross section of minimum 3 x 1.5 mm2 with capacity not less than 10A. Confi rm that external lines
have been well connected, check that the power switch is in the OFF position. Turn all temperature and speed
controls to the 0 position, open tension lever (6) to disengage pressure roller, then insert the plug.
Turn on the power and select temperature and speed, take 2 narrow pieces of material for welding trials.
Temperature selection can be di erent for the same material at di erent ambient temperature and material
thickness. To determine the best welding result, adjust the speed to approximately 2 m/min, and then make
di erent trial welds while slowly adjusting the temperature from low to high. (approximately 300 – 380 °C).
Evaluate welding parameters by carrying out tensile testing.
After temperature and speed have been determined, insert material to be welded between the two pressure
rollers, and engage the tension lever to start the welding process
Check the welded seam (welded bead/weld path). If required, correct the speed with potentiometer drive (12).
When welding is completed, disengage tension lever to prevent damage to the pressure rollers. Pressure rollers
should never run against each other without material between them.
Push On/O -button for heating and drive.
Allow device to cool-down.
Disconnect the mains voltage plug.
Perform a test welding according to the welding instructions of the material manufacturer and the
national standards or guidelines. Check the test welding.
Putting into operation
Switching o
Test weld
Error messages
Error Cause Solving
Drive no function
Motor blocked (>3 sec) After 5 sec. automatic motor restart
Motor overheated (> 85 °C) Cool down motor for 20 min then start again
Flexible drive shaft defect Change fl exible drive shaft
No or not enough heating
power
Heating cartridge defect Change heating cartridge
Temperature-probe defect Change temperature probe
Under voltage Use Extension cable with bigger load capacity.
Contact Weldy service center