AXIOMET AX-3004H [7/12] The usb charging function check
![AXIOMET AX-3004H [7/12] The usb charging function check](/views2/1665025/page7/bg7.png)
11. The USB charging function check
This is for checking USB charging function.
1) Switch on the product, the power is off and the indicators of CC & CV are light off.
2) Push and light the USB button. Adjust the voltage as 5.2V and current as 2.5A.
3) Push and light OUT button.
4) Make sure the power supply under CV mode, the CV indicator is light in LCD.
5) Setting the current value and make sure the current value can be adjusted from 0A to the maximum
value of measuring range. You cannot adjust voltage.
12. Major Specification
Input Voltage: 90VAC~265VAC 43Hz~65Hz ±2Hz
Input Current: 1A
Output Rating: Max. Voltage 0.3V~30V, Max. Current 0~3.75A
Line Regulation ±%of output + offset: Voltage CV�0.01%+3mV, Current CC�0.01%+3mA
Load Regulation ±%of output + offset: Voltage CV�0.02%+3mV, Current CC�0.02%+3mA
Measurement Accuracy: Voltage 10mV, Current 1mA
Measured Value Accuracy @ 25℃ ±%of output + offset: Voltage �0.05%+5mV, Current �0.05%+5mA
Measurement Speed: Voltage 100ms/ones, Current 100ms/ones
Setting Value Accuracy @ 25℃ ±%of output + offset: Voltage �0.05%+5mV, Current �0.05%+5mV
Ripple and Noise 20HZ-20MHZ: Voltage �10mVrms/100mVp-p, Current�10mVrms/100mVp-p
Temperature Coefficient @ 0~40℃ ±%of output + offset: Voltage �0.05%, Current �0.1%
Dimensions: 185x88x38 mm
Weight (Net): 370g
13. Supplementary Characteristic
Build-in EEPROM
Recommended Calibration Time:Annually
AC Input Power: 90-265VAC, 43 to 65 Hz
Operating Temperature: 0 to 40 ℃
Storage Temperature: -20 to 70 ℃
Содержание
- Introduction 1
- Safety 1
- Safety marks 1
- Product features 2
- Specification compliance 2
- Quick start 3
- Front panel description 4
- Pre checking 5
- Quick start 5
- Output checking 6
- Major specification 7
- Supplementary characteristic 7
- The usb charging function check 7
- Front panel 8
- Keypad description 8
- Operation 8
- Voltage setting 8
- Current setting 9
- Output switch 9
- Data saving operation 10
- Recall saving operation 10
- Usb power charging 10
- Calibration 11
- Voltage calibration 11
- Current calibration 12
Похожие устройства
- AXIOMET AX-3003L-3 Инструкция
- AXIOMET AX-3003L-3 Расширенная инструкция
- AXIOMET AX-3003D-3 Инструкция
- AXIOMET AX-3003D-3 Расширенная инструкция
- AXIOMET AX-3003D Инструкция
- AXIOMET AX-3003D Расширенная инструкция
- AXIOMET AX-1803D Инструкция
- AXIOMET AX-1803D Расширенная инструкция
- AXIOMET AX-12001DBL Инструкция
- AXIOMET AX-BCX9MM-1 Инструкция
- AXIOMET AX-BCX3 Инструкция
- AXIOMET AX-BCX2 Инструкция
- AXIOMET AX-BC6MM-1 Инструкция
- AXIOMET AX-BC3 Инструкция
- AXIOMET AX-B350 Расширенная инструкция
- AXIOMET AX-B350 Инструкция
- AXIOMET AX-B2135ST Инструкция
- AXIOMET AX-B2135ST Расширенная инструкция
- AXIOMET AX-B2135CW Инструкция
- AXIOMET AX-B2135CW Расширенная инструкция