MEAN WELL NMP1K2 [10/12] External voltage dc

MEAN WELL NMP1K2 [10/12] External voltage dc
650W/1200W Modular Power
NMP series
3.Remote Sense
The Remote Sense compensates voltage drop on the load wiring up to 0.5V.
4. Output Voltage Programming(PV)
In addition to the adjustment via the built-in potentiometer, the output voltage (default voltage set by VR60) can be trimmed by applying
“EXTERNAL VOLTAGE”.
“Output Voltage Programming (PV)” range is the same as ‘‘Voltage ADJ. Range (VR60)”
GND
1
GND
2
RC2
VCC2 CS
DC_OK
PC
CN81
PV
+S
-S
9
10
NMS-240
NMS-240
GND
( PIN1 or 2)
GND
( PIN1 or 2)
PV
( PIN8)
PC
( PIN7)
GND
GND
1
1
GND
GND
2
2
RC2
RC2
VCC2
VCC2
CS
CS
DC_OK
DC_OK
PC
PC
CN81
CN81
PV
PV
+S
+S
-S
-S
9
9
10
10
EXTERNAL
VOLTAGE (DC)
EXTERNAL
VOLTAGE (DC)
EXTERNAL VOLTAGE (VDC)
122.53456
PV (Referenced to GND)
100
120
Vout
Non-Linear
12V only
(E code)
80
60
40
50
20
OUTPUT VOLTAGE (%)
+S
( PIN9)
-S
( PIN10)
Sense lines should
be twisted in pairs
5. Constant Current Level Programming (PC)
The constant current level can be trimmed to 40~100% of the rated current by applying “EXTERNAL VOLTAGE”.
EXTERNAL VOLTAGE (VDC)
1.8 5 6
PC (Referenced to GND)
115
Iout
OLP 115% (typ.)
Non-Linear
80
100
60
40
20
OUTPUT CURRENT (%)
File Name:NMP-SPEC 2018-09-18
CN81
4
6810
97
5
3
2
1
+V
-V
-
+
LOAD
VR60
LED
+V
+V
-V
-V
-
-
+
+
LOAD
LOAD
CN81
CN81
4
4
6
6
8
8
10
10
9
9
7
7
5
5
3
3
2
2
1
1
VR60
VR60
LED
LED