De Dietrich MS 24 [81/332] Electrical connections

De Dietrich MS 24 [81/332] Electrical connections
81
71.03982.03 - EN
INSTALLATION INSTRUCTIONS
17. ELECTRICAL CONNECTIONS
18. CONNECTING THE ROOM THERMOSTAT
Access the power supply terminal block (gure 9) as described in the previous section;
remove the jumper on terminals (1) and (2);
thread the two-wire cable through the grommet and connect it to these two terminals.
This machine is only electrically safe if it is correctly connected to an efcient earth system in compliance with current
safety regulations.
Connect the boiler to a 230V single-phase earthed power supply using the supplied three-pin cable, observing correct
LIVE-NEUTRAL polarity.
Use a double-pole switch with a contact separation of at least 3 mm. When replacing the power supply cable, t a
harmonised HAR H05 VV-F’ 3x0.75mm
2
cable with a maximum diameter of 8 mm.
…Access to the power supply terminal block
disconnect the boiler from the mains power supply using the two-pole switch;
remove the two screws xing the control panel to the boiler;
rotate the control panel;
remove the cover and access the wiring area (gure 9).
The 2A fast-blowing fuse is incorporated in the power supply terminal block (to check and/or replace the fuse, pull out
the black fuse carrier).
IMPORTANT: respect polarity L (LIVE) -N (NEUTRAL).
(L) = Live (brown)
(N) = Neutral (blue)
= Earth (yellow-green)
(1) (2) = Contact for room thermostat
CG_2008 / 1009_0301
Figure 9