Daikin RXYMQ36MVJU [7/19] Preparation before operation
![Daikin RXYMQ36MVJU [7/19] Preparation before operation](/views2/1718446/page7/bg7.png)
6
Preparation Before Operation
■
■■
■
Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
■
■■
■
Operation range
If the temperature or the humidity is beyond the following conditions, safety devices may work and the air conditioner
may not operate, or sometimes, water may drop from the indoor unit.
DB: Dry bulb temperature WB: Wet bulb temperature
The setting temperature range of the remote controller is 60°F to 90°F.
Useful Information
Observe the following precautions to ensure the system operates properly.
Recommended temperature setting
For cooling 79 to 83 °F
For heating 68 to 75 °F
Cooling
INDOOR
OUTDOOR TEM-
PERATURE
TEMPERATURE HUMIDITY
DB 70 to 90 °F
80% or below
(Long time operation in a humid-
ity over 80% may cause conden-
sation on the unit and dripping.)
DB
23 to 115 °F
WB 57 to 77 °F
Heating
**–4~5°FWB: Range for operation
5~60°FWB: Range for continuous operation
INDOOR TEMPERA-
TURE
OUTDOOR
TEMPERATURE
DB 59 to 81 °F
DB –4 to 70 °F**
WB
–4 to 60 °F
**
• Set the room temperature appropriately.
Take care not to cool or heat the room excessively.
Adjust the temperature so that everyone in the room is comfortable.
• Ventilate the room from time to time.
Be sure to ventilate the room after using the air conditioner for a long time.
• Do not leave the door or window open.
The air will be released, and the effect of cooling/heating
will be reduced.
•
Do not allow direct sunshine to enter the room during the cooling
operation.
Hang a curtain or blind to the window to prevent direct sunshine
.
•
Keep televisions, radios or stereo equipment at least 3.5ft. from
the indoor unit or remote controller.
Otherwise, picture
disturbance or
noise may result.
• Turn off the power when the air conditioner is not used
for a long time.
With the power on, the air conditioner will consume several
to several tends of watts of power (∗1)
NOTE
∗1
The power consumption while the equipment is stopped var-
ies with the type of outdoor unit, etc. Consult your dealer for
further details on power consumption.
•
Do not use and room heater under the indoor unit.
Heat may deform the suction grille of indoor unit.
• Do not place things near the air outlet or air inlet.
Such obstacles may lower the performance of the air condi-
tioner or make it stop.
• When the display shows “ ” (TIME TO CLEAN AIR
FILTER), refer to the instruction manual of the indoor
unit, and clean the air filter.
01_EN_3PN00286-12Z.fm Page 6 Wednesday, September 14, 2005 8:56 PM
Содержание
- Operation manual 1
- Rxymq36mvju rxymq48mvju 1
- System air conditioner 1
- Contents 2
- Safety considerations 2
- Ask a qualified service person to perform this work 3
- Attention 5
- Brc1c71 krc19 26a 5
- I i i i 5
- Installation site 5
- Names of parts 5
- 4 5 fwb range for operation 7
- Be careful not to cool heat the room too much keeping the temperature setting at a moderate level helps save energy 7
- Blocking sunlight and air from outdoors increases the cooling heating effect 7
- Cooling 7
- Cover windows with a blind or a curtain 7
- Db dry bulb temperature wb wet bulb temperature the setting temperature range of the remote controller is 60 f to 90 f 7
- Heating 7
- Observe the following precautions to ensure the system operates properly 7
- Operation range if the temperature or the humidity is beyond the following conditions safety devices may work and the air conditioner may not operate or sometimes water may drop from the indoor unit 7
- Preparation before operation 7
- Tips for saving energy 7
- Useful information 7
- Adjustment 8
- Cooling heating fan operation 8
- Characteristics of the heating operation 9
- Cooling heating fan operation 9
- Only for fxfq fxhq fxaq 9
- Stopping the system 9
- Adjustment 10
- Only for fxfq fxhq fxaq 10
- Program dry operation 10
- Stopping the system 10
- Adjusting the air flow direction 11
- Only for fxfq fxhq fxaq 11
- On off timer operation 12
- How to set master remote controller 13
- Setting the master remote controller 13
- Contents and functions of operation 14
- How to designate the master remote controller 14
- In the case of wireless remote controllers 1 14
- Precautions for group control system or two remote controller control system 14
- Case explanation 15
- The following cases are not air conditioner troubles but have some reasons you may just continue using it 15
- These cases are not troubles 15
- Trouble shooting 15
- Call the service shop immediately 16
- Case explanation 16
- Trouble shooting 16
- Warning 16
- Action and contact 17
- After a power failure 17
- Check the following before requesting service 17
- I the power supply wire is abnormally hot or damaged i an abnormal sound is heard during operation i the safety breaker a fuse or the earth leakage circuit breaker cuts off the operation frequently i a switch or a button often fails to work properly i there is a burning smell i water leaks from the indoor unit 17
- If one of the following symptoms takes place call the service shop immediately 17
- Lightning 17
- Note check the above items and if the problem still cannot be fixed contact your dealer for repair stating the symptom s and the model name 17
- Symptom 17
- Turn the breaker off and call the service shop 17
- After sales service 18
- Caution 18
- We recommend periodical maintenance 18
- Pn00286 12z em04a030a 19
Похожие устройства
- Daikin RXYMQ48MVJU Инструкция по эксплуатации
- Daikin RZQ18PVJU Руководство по вводу в эксплуатацию
- Daikin RZQ24PVJU Спецификация
- Daikin RZQ30PVJU Спецификация
- Daikin RZQ18PVJU Инструкция по монтажу
- Daikin RZQ24PVJU Руководство по вводу в эксплуатацию
- Daikin RZQ18PVJU Технические данные
- Daikin RZQ30PVJU Руководство по вводу в эксплуатацию
- Daikin RZQ18PVJU Сервис мануал
- Daikin RZQ24PVJU Инструкция по монтажу
- Daikin RZQ30PVJU Инструкция по монтажу
- Daikin RZQ24PVJU Технические данные
- SilverStone SST-AR01 Инструкция по эксплуатации
- Daikin RZQ30PVJU Технические данные
- Daikin RZQ24PVJU Сервис мануал
- Daikin RZQ30PVJU Сервис мануал
- SilverStone SST-AR01 Документация
- SilverStone SST-AR01-V2 (adds AM4 supports) Инструкция по эксплуатации
- SilverStone SST-AR01-V2 (adds AM4 supports) Документация
- Daikin RQYQ140P Технические данные