3. PROTECTION
The power supply shall have current limit to prevent the +3.3V,+5V,and +12V1,+12V2,
+12V3 +12V4 +12V5,+12V6 outputs from exceeding the values shown in the following
Table.If the current limits are exceeded the power supply shall shutdown and latch off.
3-1. Over current protection
Voltage
+5V
3-2. Under voltage protection.
In an under voltage fault occurs, the supply will latch all DC outputs into a shutdown
state when +12V,+5V & +3.3V outputs under 85% of it's maximum value.
3-3. Over voltage protection
output
+12 VDC
+5 VDC
+3.3 VDC
Minimum
13.3
5.70
3.90
Nominal
15.0
6.3
4.2
Maximum
14.5
6.50
4.50
Unit
Volts
Volts
Volts
The over voltage sense circuitry and reference shall reside in packages that are separate
and distinct from the regulator control circuity and reference.No single point fault shall be
able to cause a sustained over voltage condition on any or all outputs. The supply shall
provide latch-mode over voltage protection as defined in Table.
Содержание
- En st1200 manual 01 1
- 1 ac input requirements 2
- Ac input 2
- Dc output 2
- En st1200 manual 02 2
- Iin 19 10 arms 2
- 1 dc voltage regulation 3
- 2 load ranges 3
- En st1200 manual 03 3
- Load range 3
- 3 output ripple 4
- En st1200 manual 04 4
- 4 overshoot 5
- 5 efficiency 5
- 6 remote on off control 5
- En st1200 manual 05 5
- The ripple voltage of the outputs shall be measured at the pins of the output connector when terminated in the load impedance specified in figure 1 ripple and noise are measured at the connectors with a 0 uf ceramic capacitor and a 10uf electrolytic capacitor to simulatesystem loading ripple shall be measured under any condition of line voltage output load line frequency operation temperature 5
- 1 over current protection 6
- 2 under voltage protection 6
- 3 over voltage protection 6
- En st1200 manual 06 6
- In an under voltage fault occurs the supply will latch all dc outputs into a shutdown state when 12v 5v 3 v outputs under 85 of it s maximum value 6
- Protection 6
- The over voltage sense circuitry and reference shall reside in packages that are separate and distinct from the regulator control circuity and reference no single point fault shall be able to cause a sustained over voltage condition on any or all outputs the supply shall provide latch mode over voltage protection as defined in table 6
- 1 signal timing drawing 7
- 1 t3 power good signal turn on delay time 100ms 500ms 7
- 2 t4 power good signal turn off delay time 1ms min 7
- 3 t5 rise time 5 70ms max 7
- 4 short circuit 7
- 4 t6 hold up time 17ms min tested at 75 of maximum load and over 100 240vac input 7
- 5 no load operation 7
- An output short circuit is defined as any output impedance of less than 0 ohms the power supply shall shut down and latch off for shorting the 3 vdc 5 vdc or 12 vdc rails to return or any other rail shorts between main output rails and 5vsb shall not cause any damage to the power supply the power supply shall either shut down and latch off or fold back for shorting the negative rails 5vsb must be capable of being shorted indefinitely but when the short is removed the powersupply shall recover automatically or by cycling ps_on the power supply shall be capable of withstanding a continuous short circuit to the output without damage or overstress to the unit 7
- En st1200 manual 07 7
- Figure 2 is a reference for signal timing for main power connector signals and 7
- Figure 2 pw ok timing sequence 7
- No damage or hazardous condition should occur with all the dc output connectors disconnected from the load the power supply may latch into the shutdown state 7
- Timing 7
- 1 iec 1000 4 2 esd level x20kv4 8
- 1 operation 8
- 1 underwriters laboratory ul recognition 8
- 2 hold up time 8
- 2 shipping and storage 8
- 2 the power supply must bear the german bauart mark from tuv 8
- Altitude 8
- Electromagnetic compatibility emc 8
- En st1200 manual 08 8
- Environment 8
- Safety 8
- The power supply designed to meet ul 8
- When the power loss its input power it shall maintain 17ms in regulation limit at normal input voltage ac 115v 60hz or 230v 50hz 8
- En st1200 manual 09 9
- En st1200 manual 10 10
- M b 24pin connector 10
- Pin peripheral connector hdd 4pin floppy connector fdd 10
- Sata connector 10
- En st1200 manual 11 11
- En st1200 manual 12 12
Похожие устройства
- SilverStone SST-ST1200 инструкция по установке
- SilverStone ST1200-G Инструкция по эксплуатации
- SilverStone ST1200-G инструкция по установке
- SilverStone SST-ST1200-G Инструкция по эксплуатации
- SilverStone SST-ST1200-G инструкция по установке
- SilverStone ST30GF Инструкция по эксплуатации
- SilverStone ST30GF инструкция по установке
- SilverStone SST-ST30GF Инструкция по эксплуатации
- SilverStone SST-ST30GF инструкция по установке
- SilverStone ST30NF Инструкция по эксплуатации
- SilverStone ST30NF инструкция по установке
- SilverStone SST-ST30NF Инструкция по эксплуатации
- SilverStone SST-ST30NF инструкция по установке
- SilverStone ST350 Инструкция по эксплуатации
- SilverStone ST350 инструкция по установке
- SilverStone SST-ST350 Инструкция по эксплуатации
- SilverStone SST-ST350 инструкция по установке
- SilverStone ST35F Инструкция по эксплуатации
- SilverStone ST35F инструкция по установке
- SilverStone SST-ST35F Инструкция по эксплуатации